![Phytec 1488.2 Скачать руководство пользователя страница 61](http://html1.mh-extra.com/html/phytec/1488-2/1488-2_hardware-manual_1554119061.webp)
PCM-065/phyCORE-i.MX8X System on Module
L-864e.A1
© PHYTEC America LLC, 2021
61
12
Hints for Integrating and Handling the phyCORE-i.MX8X
12.1
Integration
Successful integration of the phyCORE-i.MX8X SOM into target circuitry greatly depends on adherence to the
layout design rules for the ground connections of the phyCORE module. As a general design rule, we
recommend connecting all ground pins' neighboring signals which are being used in application circuitry. At
least one ground pin should be connected for every power pin used. For maximum EMI performance, all ground
pins should be connected to a solid ground plane.
Additional information is available to facilitate the integration of the phyCORE-i.MX8X SOM into customer
applications, such as:
phyCORE-i.MX8X SOM and Carrier Board Schematic Referenc
es:
•
Schematics are made available upon request
phyCORE-i.MX8X Pin Resources:
•
•
The following file is a pin muxing reference for PHYTEC Hardware:
•
The following file is a pin mux file for importing into NXP's Pin Muxing
Tool:
Phone, e-mail, FAQ, wiki, and other online support by visiting
12.2
Modification
Removal of various components, such as the microprocessor and the standard quartz, is not advisable given
the compact nature of the module. Should this nonetheless be necessary, please ensure that the board as well
as surrounding components and sockets remain undamaged while de-soldering. Overheating the board can
cause the solder pads to loosen, rendering the SOM inoperable. Carefully heat neighboring connections in pairs.
After a few alternations, components can be removed with the solder-iron tip. Alternatively, a hot air gun can be
used to heat and loosen the bonds.
WARNING:
If any modifications to the module are performed, regardless of their nature, the manufacturer guarantee is
voided.