1.3.8.
IRIG IN (External Time Synchronization)
The system supports IRIG
-
B input and can add an IRIG code to each recorded frame. The
sample timing for the IRIG code is once each frame.
The recorded IRIG code is displayed on a “PFV”.
◼
IRIG Code Input Specification
Connector
BNC
Code Format
IRIG-B (122) Analog
Amplitude
1.0Vp-p min,8.0Vp-p max
Mark to space ratio
3:1 to 6:1
Typical modulated carrier signal ratio
10:1
•
IRIG Time Code is used when synchronizing a camera with external equipment in time.
•
It is a convenient function when apparatus is physically separated.
•
When the IRIG code is being input, the IRIG code is displayed in white, and is displayed to the left.
•
The IRIG offset time is also displayed below it. When the IRIG code is not being input, the IRIG
code is displayed in grey. At that time, the counter is the camera’s internal counter and it continues
to count.
•
Limitation of use of IRIG code
With the Image Trigger function, IRIG code cannot be used when the specified number of frames
is 32 or fewer in RANDOM CENTER or RANDOM MANUAL trigger mode.
Содержание FASTCAM Nova
Страница 1: ...FASTCAM Nova Hardware Manual...
Страница 29: ...16 FASTCAM Nova 1 3 Input Output Signal Types 1 3 3 IO INPUT Circuit Diagram...
Страница 42: ...2 Capter 2 Recording This chapter explains operations related to recording...
Страница 45: ...3 Capter 3 Product Specifications This chapter explains the system s specifications...
Страница 66: ...53 FASTCAM Nova 3 2 Dimensions Sencor position EF mount mm 1 1 Sensor Cover Glass 44 3 Image Sensor Position...
Страница 67: ...54 FASTCAM Nova 3 2 Dimensions 3 2 2 AC Power Supply Unit mm...
Страница 68: ...4 3 Capter 4 Warranty This chapter explains about the warranty...