background image

Voltage parameters given for a 12V system. For a 24V system, these values are doubled. For lithium batteries, please refer to 
the controller's user manual.

Num

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

Name

Time1

Dim1

Time2

Dim2

Time3

Dim3

Time4

Dim4

Time5

Dim5

D/N Thr

D/N Dly

Load I

Dim Auto

Dim V

Dim %

Battery

CVT

CVR

LVD

LVR

0℃ Chg

DelayOff

Dim NP

Range

*1

0~6.5H+24H+D2D 

0~100%

0~7.5H

0~100%

0~7.5H

0~100%

0~7.0H+T0T

0~100%

0~7.5H

0~100%

3.0~20.0V

0~30min

0.15~6.0A

*2

Yes/No/365

         

*3

8.0~32.0V      

 

1~20%

*4

LIQ/GEL/LI        

8.0~32.0V

*5

7.5~31.8V       

10.8~11.8V,

*6

Soc1~Soc5     

 

*7

11.4~12.8V     

*8

Yes/No/Slow

  

*9

10~150s         

 

0~100%           

Step Length

0.5H

10%

0.5H

10%

0.5H

10%

0.5H

10%

0.5H

10%

0.5V

5min

0.05A

0.1V

1%

0.1V

0.1V

0.1V

0.1V

10s

10%

    Factory Default

4H

100%

0H

100%

0H

100%

0H

0%

0H

100%

5V

0min

0.3A

Yes

12.5V

10%

GEL

14.6V

14.0V

11.0V

12.0V

Yes

10s

10%

Description

The first working time for load
Dimming of the first working time
The second working time for load
Dimming of the second working time
Third working time for load
Dimming of the third working time
Fourth working time for load
Dimming of the fourth working time
Fifth working time for load
Dimming of the fifth working time

Day/Night Threshold voltage

Day/Night open load delay time

Load current

Automatic dimming

The voltage to start dimming 

Automatic dimming percentage

Battery type

Charging voltage target

Charging voltage recovery

Low voltage disconnect

Low voltage reconnect

0℃ Charging Protection

Sensing delay off time

Dimming when no people

7.

 

Parameters setting

Smart Remote Programmer LUX-PRG User Manual

Page 4 of 5

1.

If "Time1" is set to "24H" the load will be on constantly

2.

Select "Yes" to activate "Dim V" and "Dim %" settings. 365 setting is only applicable to Lithium series controllers.

3.

For a Lithium battery, "Dim V" should not be greater than the "CVT". For gel or liquid batteries, "Dim V" should not be 

greater than 12.5V.

4.

If "LI" is selected as the battery type, "CVT" and "CVR" settings will display.

5.

"CVR" should be less than "CVT" by 0.2~1.5V. Before reducing "CVT" first reduce "CVR".

6.

Soc 1-5 are the 5 State of Charge states for the battery. 

The data in the table is for gel or liquid batteries only. When "LI" 

is selected as the battery type, the range for "LVD" is 6.0~30.0V and the range for "LVR" is 6.6~31.0V

7.

"LVR" should be less than "LVD" by >0.6V. Before increasing "LVD" first increase "LVR".

8.

"0°C Chg" is designed for 

some

 Lithium series controller

s

. When the controller detects an ambient temperature lower 

than 0°C, it will:

If the setting is "Yes" operation will continue as normal

If the setting is "No" charging will stop

If the setting is "Slow" charging will continue at 20% of the rated current

9.

"DelayOff" is the time taken for the 

movement

 sensing controllers to deactivate the load when no nearby movement is 

detected

 in "Time2" and "Time4" periods

.

10.

 "Dim NP" is the load power setting when no movement is detected by the 

movement

 sensing controller in "Time2" 

and 

"Time4" periods.

Содержание LUX-PRG

Страница 1: ...LUX PRG Remote Programmer User Manual This user manual is subject to change without notice ...

Страница 2: ...t the setting Read Parameters Read running status Turn on the LCD backlight 1 Turn on the emergency lighting 2 SOS lights switch Continuously increase the setting data Continuously decrease the setting data Press Light and Set key to lock or unlock the parameters Press Set and Light key to lock or unlock the parameters Thank you for choosing the LUX PRG series infrared remote programmer This remot...

Страница 3: ...te this feature may vary for different controllers please refer to the charge controller user manual 5 6 Transport mode Press and hold the Back and Backlight key for 3s The programmer will beep two short sounds The upper left of the menu will change from Setting to Transport For the lithium series controller press the Test key the remote will show Transport OK and emit a long beep as the controlle...

Страница 4: ...prevent accidental operation To unlock press and hold Set and Light for 3s again The remote will beep one short sound and the unlocked symbol will display 5 11 Buzzer Beep length Instruction A short sound Two short sounds Three short sounds A long sound Unlock Key lock Communication successful Communication failure Num 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Name Status Batt V Load I Load V PV V PV I Ene...

Страница 5: ...Charging voltage recovery Low voltage disconnect Low voltage reconnect 0 Charging Protection Sensing delay off time Dimming when no people 7 Parameters setting Smart Remote Programmer LUX PRG User Manual Page 4 of 5 1 If Time1 is set to 24H the load will be on constantly 2 Select Yes to activate Dim V and Dim settings 365 setting is only applicable to Lithium series controllers 3 For a Lithium bat...

Страница 6: ... Data 1 0H 100 2 0H 80 3 0H 60 T0T 40 2 0H 100 10s 10 Using the settings above the controller would work as follows 1 After the sun sets the load is powered at 100 for 1 hour 2 The load is then lit at 80 for 2 hours 3 For 3 hours the load is powered at 60 when movement is detected and at 6 60 x 10 when movement is not detected 4 Until 2 hours before dawn based on previous data the load is powered ...

Отзывы: