Voltage parameters given for a 12V system. For a 24V system, these values are doubled. For lithium batteries, please refer to
the controller's user manual.
Num
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
Name
Time1
Dim1
Time2
Dim2
Time3
Dim3
Time4
Dim4
Time5
Dim5
D/N Thr
D/N Dly
Load I
Dim Auto
Dim V
Dim %
Battery
CVT
CVR
LVD
LVR
0℃ Chg
DelayOff
Dim NP
Range
*1
0~6.5H+24H+D2D
0~100%
0~7.5H
0~100%
0~7.5H
0~100%
0~7.0H+T0T
0~100%
0~7.5H
0~100%
3.0~20.0V
0~30min
0.15~6.0A
*2
Yes/No/365
*3
8.0~32.0V
1~20%
*4
LIQ/GEL/LI
8.0~32.0V
*5
7.5~31.8V
10.8~11.8V,
*6
Soc1~Soc5
*7
11.4~12.8V
*8
Yes/No/Slow
*9
10~150s
0~100%
Step Length
0.5H
10%
0.5H
10%
0.5H
10%
0.5H
10%
0.5H
10%
0.5V
5min
0.05A
—
0.1V
1%
—
0.1V
0.1V
0.1V
0.1V
—
10s
10%
Factory Default
4H
100%
0H
100%
0H
100%
0H
0%
0H
100%
5V
0min
0.3A
Yes
12.5V
10%
GEL
14.6V
14.0V
11.0V
12.0V
Yes
10s
10%
Description
The first working time for load
Dimming of the first working time
The second working time for load
Dimming of the second working time
Third working time for load
Dimming of the third working time
Fourth working time for load
Dimming of the fourth working time
Fifth working time for load
Dimming of the fifth working time
Day/Night Threshold voltage
Day/Night open load delay time
Load current
Automatic dimming
The voltage to start dimming
Automatic dimming percentage
Battery type
Charging voltage target
Charging voltage recovery
Low voltage disconnect
Low voltage reconnect
0℃ Charging Protection
Sensing delay off time
Dimming when no people
7.
Parameters setting
Smart Remote Programmer LUX-PRG User Manual
Page 4 of 5
1.
If "Time1" is set to "24H" the load will be on constantly
2.
Select "Yes" to activate "Dim V" and "Dim %" settings. 365 setting is only applicable to Lithium series controllers.
3.
For a Lithium battery, "Dim V" should not be greater than the "CVT". For gel or liquid batteries, "Dim V" should not be
greater than 12.5V.
4.
If "LI" is selected as the battery type, "CVT" and "CVR" settings will display.
5.
"CVR" should be less than "CVT" by 0.2~1.5V. Before reducing "CVT" first reduce "CVR".
6.
Soc 1-5 are the 5 State of Charge states for the battery.
The data in the table is for gel or liquid batteries only. When "LI"
is selected as the battery type, the range for "LVD" is 6.0~30.0V and the range for "LVR" is 6.6~31.0V
7.
"LVR" should be less than "LVD" by >0.6V. Before increasing "LVD" first increase "LVR".
8.
"0°C Chg" is designed for
some
Lithium series controller
s
. When the controller detects an ambient temperature lower
than 0°C, it will:
If the setting is "Yes" operation will continue as normal
If the setting is "No" charging will stop
If the setting is "Slow" charging will continue at 20% of the rated current
9.
"DelayOff" is the time taken for the
movement
sensing controllers to deactivate the load when no nearby movement is
detected
in "Time2" and "Time4" periods
.
10.
"Dim NP" is the load power setting when no movement is detected by the
movement
sensing controller in "Time2"
and
"Time4" periods.