5.7 Read
5.7.1 Read parameters
Aim at the solar charge controller and press the
"
Parameter
" key, the remote programmer will read the
settings of the controller. If successful, the remote will
emit a long beep and display the setting values.
You can press the "
" keys to navigate through the
parameters, press the "
Back
" key to return to the
previous page. If failed, the remote will display "
Read
Failure
" and beep three short sounds. After 4s the
remote programmer will return to the previous page.
5.7.2 Read the running status
Aim at the solar charge controller and press the
"
Status
" key, the remote programmer will read the
status
of the controller. If successful, the remote will
emit a long beep and display the running status.
You can press the "
" keys to navigate through the
data, press the "Back" key to return to the previous
page. For details refer to
6. Running status
.
If failed,
the remote will display "
Read Failure
" and beep three
short sounds. After 4s the remote programmer will
return to the previous page.
Note: the "
Send
" key is disabled while displaying
parameters or status.
5.8 Backlight
Press the "
Backlight
" key to turn on the backlight of
the LCD screen. This will make the screen more visible
in dark conditions.
5.9
Light
Press the "
Light
" key, the emergency light will turn on.
Press again to switch to the SOS beacon. Press the key
a third time and the light will turn off. The light will
shut down automatically after 30 seconds.
5.10 Lock
Press and hold the "
Set
" and "
Light
" key for 3s. The
remote programmer will beep two short sounds and
the "
Set
" key will lock to prevent accidental operation.
To unlock, press and hold "
Set
" and "
Light
" for 3s
again. The remote will beep one short sound and the
unlocked symbol will display.
5.11 Buzzer
Beep length
Instruction
(A short sound)
(Two short sounds)
(Three short sounds)
(A long sound)
Unlock
Key lock
Communication
successful
Communication failure
Num
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Name
Status
:
Batt V
Load I
Load V
PV
V
PV
I
Energy
OD Times
FC Times
Day1-HV
Day1-LV
Day2-HV
Day2-LV
Day3-HV
Day3-LV
Description
Charge
Battery voltage
Load current
Load voltage
PV voltage
PV current *
Total generating capacity
Over discharge times
Fully charge times
A day ago highest voltage
A day ago lowest voltage
Two days ago highest voltage
Two days ago lowest voltage
Three days ago highest voltage
Three days ago lowest voltage
Unit
V
A
V
V
A
AH
Time
Time
V
V
V
V
V
V
When you press the "
Status
" key, the first line of the
LCD displays the system status, including charging,
discharging or converting between charging and
discharging.
If the controller's protective features have been
activated, the remote programmer will display this as a
priority over the running status.
If any of the fault warnings appear on the display, please
refer to the controller's manual for troubleshooting.
Name
Charge
Discharge
Convert
Over CD
Short CD
Low VD
Over VP
Over TD
Open CP
HardwareP
Description
C
harging
D
ischarging
Charge/discharge conversion
Over current disconnect
Short circuit disconnect
Low voltage disconnect
Over voltage protection
Over temperature disconnect
Open circuit protection
Hardware protection
6. Running status
Note: * some types of controller are unable to detect PV
current. The remote programmer will display "---" if this is
the case.
Smart Remote Programmer LUX-PRG User Manual