5.2 Trigger and Strobe
5.2.8
Trigger Timing Values
Table 5.4 shows the values of the trigger timing parameters.
Timing Parameter
Minimum
Maximum
t
d
−
iso
−
input
1
µ
s
1.5
µ
s
t
d
−
RS422
−
input
65 ns
185 ns
t
jitter
0
25 ns
t
trigger
−
delay
0
0.42 s
t
burst
−
trigger
−
delay
0
0.42 s
t
burst
−
period
−
time
depends on camera settings
0.42 s
t
trigger
−
offset
(non burst mode)
200 ns
duration of 1 row
t
trigger
−
offset
(burst mode)
250 ns
250 ns
t
exposure
15
µ
s
1)
/ 28
µ
s
0.42 s
t
strobe
−
delay
600 ns
0.42 s
t
strobe
−
offset
(non burst mode)
200 ns
200 ns
t
strobe
−
offset
(burst mode)
250 ns
250 ns
t
strobe
−
duration
200 ns
0.42 s
t
d
−
iso
−
output
150 ns
350 ns
t
trigger
−
pulsewidth
200 ns
n/a
Number of bursts n
1
30000
Table 5.4: Summary of timing parameters relevant in the external trigger mode
.
MAN077 11/2017 V1.0
55 of 139
Содержание MV1-D1280-L01-1280-G2-12
Страница 1: ...Photonfocus MV1 D1280 L01 Camera Series CMOS camera with GigE interface MAN077 11 2017 V1 0...
Страница 10: ...1 Preface 10 of 139 MAN077 11 2017 V1 0...
Страница 16: ...3 How to get started GigE G2 Figure 3 3 PFInstaller components choice 16 of 139 MAN077 11 2017 V1 0...
Страница 84: ...5 Functionality 84 of 139 MAN077 11 2017 V1 0...
Страница 88: ...6 Precautions 88 of 139 MAN077 11 2017 V1 0...
Страница 120: ...8 Software 120 of 139 MAN077 11 2017 V1 0...
Страница 130: ...12 Support and Repair 130 of 139 MAN077 11 2017 V1 0...
Страница 132: ...13 References 132 of 139 MAN077 11 2017 V1 0...
Страница 136: ...B Camera Revisions 136 of 139 MAN077 11 2017 V1 0...
Страница 138: ...C Feature Matrix 138 of 139 MAN077 11 2017 V1 0...
Страница 139: ...D Document Revision History Revision Date Changes 1 0 November 2017 First version MAN077 11 2017 V1 0 139 of 139...