7.5.5
Predefined LUT settings
Some predefined LUT are stored in the camera. To activate a predefined LUT:
1.
Select LUT and RegionLUT (if required) as described in Section 7.5.2 and Section 7.5.3.
2.
Set
LUTAutoMode
(in category
LUTControl
) to the desired value. The available settings are
described in property list of the camera which is contained in the PFInstaller.
3.
If the
LUTAutoMode
requires additional settings (e.g. Gamma
LUTAutoMode
), then it can be set
with
LUTAutoValue
.
7.6
MROI
The MROI feature is described in Section 5.1.2. This section describes how to set the MROI
values.
When MROI is enabled, then the camera internally processes the MROI entries sequentially,
starting at
MROI_Index
0. The processing is stopped when either the last
MROI_Index
is reached or
when an entry with
MROI_H
= 0 is reached.
Procedure to write MROI entries:
1.
Disable MROI by setting
MROI_Enable
to False. This is mandatory otherwise setting the
MROI entries will be ignored.
2.
Set
MROI_Index
. In the first run it is set to 0 and then incremented in every run.
3.
Set
MROI_Y
to the starting row of the MROI.
4.
Set
MROI_H
to the height of the MROI.
5.
Proceed with step 2, incrementing the
MROI_Index
. If no more MROI should be set, then
run the steps 2 to 4 again (incrementing
MROI_Index
) but set
MROI_H
to 0.
6.
Enable MROI by setting
MROI_Enable
to True.
7.
Read the property
MROI_Htot
. Set the property
Height
(in category
ImageFormatControl
) to
the value of
MROI_Htot
. This is mandatory as this value is not automatically updated.
Example pseudo-code to set two MROI: The resulting total height of the example will be 400.
SetFeature(’MROI_Enable’, false);
SetFeature(’MROI_Index’, 0);
SetFeature(’MROI_Y’, 50);
SetFeature(’MROI_H’, 100);
SetFeature(’MROI_Index’, 1);
SetFeature(’MROI_Y’, 600);
SetFeature(’MROI_H’, 300);
SetFeature(’MROI_Index’, 2);
SetFeature(’MROI_H’, 0);
SetFeature(’MROI_Enable’, true);
int heightTot;
GetFeature(’MROI_Htot’, &heightTot);
SetFeature(’Height’, heightTot);
7.6 MROI
99
Содержание DR1-D3360-192-G2-8
Страница 1: ...MAN071 03 2015 V1 0 Photonfocus MV1 D3360 G2 Camera Series CMOS camera with GigE interface...
Страница 10: ...3 How to get started GigE G2 Figure 3 3 PFInstaller components choice 10...
Страница 22: ...4 Product Speci cation Figure 4 1 Photonfocus D3360 GigE camera series with C mount lens 22...
Страница 76: ...5 Functionality 76...
Страница 92: ...6 Hardware Interface 92...
Страница 112: ...9 Warranty 112...
Страница 114: ...10 References 114...
Страница 117: ...B Camera Revisions B 1 General Remarks This chapter lists differences between the revisions of the camera models 117...
Страница 119: ...C Document Revision History Revision Date Changes 1 0 March 2016 First version 119...