![Photon Focus D-2048 CameraLink Series Скачать руководство пользователя страница 48](http://html1.mh-extra.com/html/photon-focus/d-2048-cameralink-series/d-2048-cameralink-series_user-manual_1553519048.webp)
5 Functionality
Counter reset by an external signal is important if you would like to synchronize
multiple cameras. One signal is applied to all cameras which resets the coun-
ters simultaneously. The timestamps of all cameras are then theoretically syn-
chronous with each other. In practice every camera runs on its own clock source
which has a precision of +/- 30 ppm and therefore the values of the timestamp
(real time counter) of the cameras may diverge with time. If this is an issue, then
the counters could be reset periodically by the external signal.
The counter reset by an external signal feature is not available on all camera
revisions, see Appendix B for a list of available features.
5.2.10
Strobe Output
The strobe output is an opto-isolated output located on the power supply connector that can
be used to trigger a strobe. The strobe output can be used both in free-running and in trigger
mode. There is a programmable delay available to adjust the strobe pulse to your application.
The strobe output needs a separate power supply. Please see Section 6.1.3 and
Fig. 5.16 and Fig. 5.17 for more information.
.
46
Содержание D-2048 CameraLink Series
Страница 1: ...User Manual Photonfocus D L 2048 CameraLink Series CMOS Area Scan Camera MAN054 11 2013 V1 3...
Страница 2: ......
Страница 4: ...2...
Страница 8: ...CONTENTS 6...
Страница 16: ...3 How to get started CameraLink Figure 3 4 PFRemote start window 14...
Страница 92: ...8 Graphical User Interface GUI 90...
Страница 94: ...9 Mechanical Considerations 92...
Страница 96: ...10 Warranty 94...
Страница 98: ...11 References 96...
Страница 102: ...A Pinouts 100...
Страница 108: ...B Camera Revisions 106...