SPECIFICATIONS 

AKC320 & AKC320B 

 
General: 
 

Flash Power....................................................10 to 320 watt-seconds. 
                                                                              (6 f-stops) 
Flash Duration................................................1/120 second at Full 

1/400 second at ½ 
1/840 second at ¼ 
1/1660 second at 1/8 
1/2900 second at 1/16 
1/4800 second at 1/32 

Recycling time................................................0.02 to 3 seconds 
Power Control.................................................Full to 1/32 range.  

(6 f-stops)  
0.1 f-stop resolution. 

Flash Color......................................................5400

±

200

°

 Kelvin 

Modeling Light Power ...................................100 Watt, 120 VAC, ESR. 
Modeling Light Control .................................ON or OFF. 
Triggering ......................................................Built in Photoslave. 

   Push 

to 

Test 

button. 

Synchronization Jack. 

Main Supply .................................................105-125 VAC, 50/60 Hz, 3 amp. 
Consumption ................................................  1 amps idling,  

5 amps charge. 

Overload Protection .......................................Fuse. 3AG type,  

8 Amp, SLO-BLO.  

Packaging .......................................................Molded, high-impact, plastic 
case. 
Weight ............................................................2 pounds, 8 ounces. 
Dimensions (housing only).............................5.25”W x 5.25”H x 7”L 
 

 

Flashtubes and Modeling Lamps: 
 

Flashtube ....................................................Plug-in style, use only  

Photogenic’s Standard  
C4-12C 

Modeling Lamp ..........................................100-Watt, 120 VAC, 
ESR. 
                                                                    [NO LARGER] 
WATTAGE] 
Fuse ............................................................3AG type, 8 Amp, SLO- 
 

 

 

 

 

BLO. 

 

Содержание AKC160

Страница 1: ...Daylight Corrected Constant Color StudioMax III Operator s Manual Studio Max III AKC320 Studio Max III AKC320B Studio Max III AKC160 Studio Max III AKC160B...

Страница 2: ...cessories include all Photogenic Quick Change reflectors and their attachments gels grids etc and soft boxes INTRODUCTION The StudioMax III s are self contained light units and power supplies They hav...

Страница 3: ...reater rating and has a ground 4 Do not insert a screwdriver or other metal objects into the flashtube socket area or vents Contact with high voltage may result 5 Do not operate this appliance with a...

Страница 4: ...contacts during operation Do not touch the glass tubes with bare hands as normal body oils will shorten the bulb s life Always use a clean cloth or wear gloves to protect your hand from glass breakag...

Страница 5: ...quick change attachments CONTROL PANEL AND BASIC OPERATION Power Input The power required to operate the StudioMax III is 105 to 125 volts AC 50 60 Hz 4 Amp and or for a B battery model an approved D...

Страница 6: ...modeling light If using a battery model B with a battery pack turn ON the AKC unit before turning the battery pack power ON Flash Power All settings and controls of the StudioMax III are extremely sta...

Страница 7: ...a daisy chain connection of all SYNC jacks It is best to connect the fill light directly to the camera since it will be positioned furthest back in the studio and will usually provide sufficient illu...

Страница 8: ...or over 320 flashes and the ADC320B for over 160 flashes at FULL power QUICK CHANGE ACCESSORIES Reflectors PL3R Shallow Background reflector PL3RV Background veil cutout reflector PL5AR 5 Deep Conical...

Страница 9: ...shes Full Continuous 15 Continuous 30 minutes 10 180 1 minutes 4 15 1 4 Continuous 10 Continuous 30 minutes 6 300 3 minutes 4 45 1 32 1 5 Continuous Exposure Information The following charts give the...

Страница 10: ...g Light Power 100 Watt 120 VAC ESR Modeling Light Control ON or OFF Triggering Built in Photoslave Push to Test button Synchronization Jack Main Supply 105 125 VAC 50 60 Hz 3 amp Consumption 1 amps id...

Страница 11: ...g Light Power 100 Watt 120 VAC S3629 Modeling Light Control ON or OFF Triggering Built in Photoslave Push to Test button Synchronization Jack Main Supply 105 125 VAC 50 60 Hz 3 amp Consumption 1 amps...

Страница 12: ...over all power levels Both are necessary to provide the perfect exposure we all strive for The light produced by the new AKC s is consistent constant Every time you set a desired power level you will...

Страница 13: ...der low light conditions you may have to extend your exposure times to a point of significant speed loss With black and white films the effect of this speed loss is partially offset by wide exposure l...

Страница 14: ...FF for four hours to discharge the main capacitors Never place your fingers or any metal objects into the flash or modeling sockets Contact with high voltage may result Limited StudioMax III Warranty...

Страница 15: ...b Bright light falling on photoslave c Poor connection in line cord d Reverse connection on trigger cord connection at camera e Some radio slaves will cause interference Consult slave manufacturer Tri...

Страница 16: ...16 Photogenic Professional Lighting 1268 Humbracht Circle Bartlett Illinois 60103 1631 USA Phone 630 830 2500 Fax 630 830 2525 Manual 016338 00 Revision 01 6 2005...

Отзывы: