PhotoCentric Liquid Crystal Dental Скачать руководство пользователя страница 10

15

DENTAL

Liquid Crystal

DENTAL

Liquid Crystal

10. Take the weight of the print arm in one hand 

11. Lower the print arm until the bolts hit the bottom 

of their slots, select ‘NEXT’

12. Return the print platform to the printer and 

tighten the turn knob firmly

13. Use the 5 mm hex key to loosen the bolt shown, 

it should be easy to tilt the print platform from side 

to side

14. Select ‘NEXT’

15.  Place  the  calibration  film  (provided)  over  the 

screen

NOTE 

The  calibration  film  represents  the  resin  vat  film 

during the platform calibration process.  A spare 

vat film can be used in its place.

NOTE

Make sure the print platform is approximately 

horizontal before proceeding.  Failure to do so 

could result in damage to the screen.

16. Close the printer hood and select ‘NEXT’, the z 

axis will move to the bottom of its travel

17. Ensure the print platform is sitting square in the 

machine, use the screen as a visual reference
18. Select ‘NEXT’

19. Whilst maintaining a light downward pressure 

on the print arm, finger-tighten the bolt shown
20. Keeping pressure on the print arm, use the 

5 mm hex key to tighten the bolt

21. Select ‘NEXT’

22. Keeping pressure on the print arm, use the 3 

mm hex key to tighten the two bolts shown

23. Visually check that the print platform is in full 

contact with the screen

24.  Close the printer hood and select ‘NEXT’, the 
z axis will move to the top of its travel

16

Содержание Liquid Crystal Dental

Страница 1: ...up com UK USA DISPOSAL INSTRUCTIONS Do not throw this electronic device into the waste when discarding To minimize pollu tion and ensure utmost protection of the global environment please recycle or return to Photocentric for recycling THE NEXT GENERATION OF 3D PRINTING IS HERE DENTAL Liquid Crystal DENTAL Liquid Crystal LC DENTAL USER MANUAL Revision 4 21 09 2020 ...

Страница 2: ...nter Set Up 5 2 Connecting to a Network 5 3 Photocentric Studio Setup 6 Printing 7 Cleaning Prints 8 Finishing Prints 9 Maintenance 9 1 Replacing the Resin Vat Film and Gasket 9 2 Print Platform and Resin Vat Re Calibration 9 3 General Maintenance 1 2 3 4 5 7 5 6 7 7 7 11 11 12 12 16 12 14 14 17 17 DENTAL Liquid Crystal ...

Страница 3: ...andard for residential commercial and light industrial environments BS EN 62368 1 2014 A11 2017 Audio video information and communication technology equipment Safety requirements 7 The technical file is available from the manufacturer at the address above 8 Additional information Signed for and on behalf of Photocentric Ltd Place of issue Peterborough Date of issue 13th January 2020 Name Paul Holt...

Страница 4: ... not be operated in direct light from the sun or any UV light source Liquid Crystal Dental should be operated in an ambient temperature of 15 C 25 C Liquid Crystal Dental should be operated in a well ventilated room Do not operate Liquid Crystal Dental with the hood open as you may be exposed to crush hazards harmful UV light or other hazards Photopolymer resin is an irritant Always wear gloves an...

Страница 5: ...USB port for printer connection via a Wi Fi network Plug a network cable eg CAT6 into the RJ45 socket if you would like to access your printer via a wired network connection The rear SD card slot should only be used by trained service personnel 5 2 CONNECTING TO A NETWORK Once your Liquid Crystal Dental is switched on if you have plugged in a network cable or Wi Fi dongle you can connect it to a n...

Страница 6: ... a failed print 3 Load the print platform into the printer you should feel a positive click 4 Tighten the turn knob firmly to lock the print platform in place 5 Ensure that the resin vat is completely clean and dry to avoid print failures or damage 6 Check the vat film for signs of damage or wear if you have any doubt about the condition of the vat film refer to section 9 1 NOTE Printing with a da...

Страница 7: ...creen may be damaged contact your supplier or visit the support pages of the Photocentric website 39 Store the resin vat inside the printer when not in use 40 Check the screen protector 41 If any Photocentric Resin Cleaner is left on the print platform clean it off with a suitable solvent such as IPA dry it thoroughly NOTE A residue of Photocentric Resin Cleaner on the print platform may prevent t...

Страница 8: ...ded from this webpage https photocentricgroup com curem support Here you can also browse guidance on the following Using your cure unit Programs Maintenance Environmental Operating Conditions 9 MAINTENANCE 9 1 REPLACING THE RESIN VAT FILM AND GASKET In normal operation you should replace the resin vat film and gasket after approximately 50 hours of printing You should immediately replace the film ...

Страница 9: ...gertip not a fingernail to check the tension There should be a high pitched resonant sound like a small drum If the film feels loose the vat will not function properly 9 2 PRINT PLATFORM AND RESIN VAT RE CALIBRATION The print platform has been pre calibrated on our production line according to strict QC procedures This ensures that the bottom surface of the print platform is parallel with the LCD ...

Страница 10: ... Make sure the print platform is approximately horizontal before proceeding Failure to do so could result in damage to the screen 16 Close the printer hood and select NEXT the z axis will move to the bottom of its travel 17 Ensure the print platform is sitting square in the machine use the screen as a visual reference 18 Select NEXT 19 Whilst maintaining a light downward pressure on the print arm ...

Страница 11: ...dustwillaccumulateontheairfilter Excessive dust will reduce the air flow and could cause the printer to overheat This will eventually trigger the thermal cut out and cause a print failure The LCD screen may also be permanently damaged Cleanthefanfilteratleastonceamonthiftheprinter is in regular use For printers in constant use or in dusty environments clean the fan filter every two weeks The filte...

Отзывы: