manualshive.com logo in svg
background image

English     

1.  Read  these  instructions  before  operating  this 

apparatus.

2.  Keep these instructions for future reference.
3.  Heed all warnings to ensure safe operation.
4.  Follow all instructions provided in this document.
5.  Do not use this apparatus near water or in locations 

where condensation may occur.

6.  Clean only with dry cloth. Do not use aerosol or liquid 

cleaners. Unplug this apparatus before cleaning.

7.  Do not block any of the ventilation openings. Install 

in accordance with the manufacturer’s instructions.

8.  Do not install near any heat sources such as radiators, 

heat registers, stoves, or other apparatus (including 

.

9.  Do not defeat the safety purpose of the polarized or 

grounding-type plug. A polarized plug has two blades 
with one wider than the other. A grounding type plug 
has two blades and a third grounding prong. The wide 
blade or the third prong is provided for your safety. If 
the provided plug does not   into your outlet, consult 
an electrician for replacement of the obsolete outlet.

10. Protect  the  power  cord  from  being  walked  on  or 

pinched particularly at plug, convenience receptacles, 
and the point where they exit from the apparatus.

11.  Only use attachments/accessories 

 by the 

manufacturer.

12. Use  only  with  a  cart,  stand,  tripod,  bracket,  or 

table 

  by  the  manufacturer,  or  sold  with 

the  apparatus.  When  a  cart  is  used,  use  caution 
when  moving  the  cart/apparatus 
combination to avoid injury from tip-
over.

13. Unplug this apparatus during lighting 

storms  or  when  unused  for  long 
periods of time.

14. Refer  all  servicing  to 

  service    personnel. 

Servicing is required when the apparatus has been 
damaged in any way, such as power-supply cord or 
plug is damaged, liquid has been spilled or objects 
have  fallen  into  the  apparatus,  the  apparatus  has 
been exposed to rain or moisture, does not operate 
normally, or has been dropped.

IMPORTANT SAFETY INSTRUCTIONS

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,

DO NOT REMOVE COVER (OR BACK)

NO USER SERVICEABLE PARTS INSIDE

REFER SERVICING TO QUALIFIED PERSONNEL

The  lightning  flash  with  arrowhead  symbol,  within  an 
equilateral  triangle,  is  intended  to  alert  the  user  to  the 
presence  of  uninsulated  “dangerous  voltage”  within  the 
product’

 

magnitude to constitute a risk of electric shock to persons.

The exclamation point within an equilateral triangle is in-
tended to alert the user to the presence of important operat-
ing and maintenance (servicing) instructions in the literature 
accompanying the appliance.

WARNING: 

To reduce the risk of 

 or electric shock, do 

not expose this apparatus to rain or moisture.

CAUTION: 

Use of controls or adjustments or performance 

of  procedures  other  than  those 

  may  result  in 

hazardous radiation exposure.

The apparatus shall not be exposed to dripping or splashing and that no objects 

 with liquids, such as vases, 

shall be placed on the apparatus. The MAINS plug is used as the disconnect device, the disconnect device shall 
remain readily operable. 

Warning

: the user shall not place this apparatus in the 

 area during the operation so that the mains switch 

can be easily accessible. 

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

Содержание AM1204FX RW

Страница 1: ...AM1204FX USBR AM1204FX AM1204FX USBR User s Manual Manual del Usuario...

Страница 2: ...COMPACT MIXERS MEZCLADORAS COMPACTAS ENGLISH I ESPA OL II APPENIX III V1 2 08 12 2016 English Espa ol AM1204FX AM1204FX USBR...

Страница 3: ...CONNECTION 2 MAKING CONNECTIONS 3 CONTROLS AND SETTINGS 4 SPECIFICATIONS 8 APPENDIX DIGITAL EFFECT TABLE 1 APPLICATION 2 DIMENSIONS 3 CONTENTS USER S MANUAL Phonic reserves the right to improve or alt...

Страница 4: ...lighting storms or when unused for long periods of time 14 Refer all servicing to service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or p...

Страница 5: ...t engine with 16 EFX each with their own user adjustable parameter Variable compressor function on mono channels ideal for vocals and drums EFX sends on each channel for creating monitor mixes and inc...

Страница 6: ...signal from your computer back to the 2T Returns the signal of which is controlled by the 2T USB Return control If there are input signals from both the USBR interface and the 2T Return the two signal...

Страница 7: ...s not work in reverse however 4 AUX Returns These 1 4 TS inputs are for the return of audio to the AM1204FX and AM1204FX USBR mixers processed by an external signal processor If really needed they can...

Страница 8: ...tom power will be accompanied by an illuminated LED above the left channel level meter Before turning Phantom Power on turn all level controls to a minimum to avoid the possibility of a ghastly poppin...

Страница 9: ...luminate when the device hits high peaks 6 dB before overload occurs It is best to adjust the gain of the channel so that the PEAK indicator lights up on intervals only if at all This will ensure a gr...

Страница 10: ...to select one of the 16 built in digital effects of the AM mixer The effect names that correspond with the numbers can be found on the top of the mixer s face or in the digital effect table 34 Paramet...

Страница 11: ...vel Meter The mixer s stereo 11 segment level meter gives an accurate indication of when audio levels of the MAIN L R output reach certain levels It is suggested for the maximum use of audio to set th...

Страница 12: ...Control 60 mm fader 60 mm fader Level Meter 11 segment 11 segment Phantom Power Supply 48V DC 48V DC Frequency Response Mic input to any output 20Hz 60KHz 0 1 dB 0 1 dB 20Hz 100KHz 0 3 dB 0 3 dB Cross...

Страница 13: ...w EQ 80Hz 80Hz Mid EQ 2 5 kHz 2 5 kHz Hi EQ 12 kHz 12 kHz Low Cut Filter 75 Hz 18 dB oct 75 Hz 18 dB oct USB Audio Stereo In Out Connector Type USB Type B Bitrate 16 bit Sampling Rate 48 kHz USB Playe...

Страница 14: ...dence of the date of purchase You will need it for any warranty service No returns or repairs will be accepted without a proper RMA number return merchandise authorization In order to keep this warran...

Страница 15: ...OR 2 CONEXIONES 3 CONTROLES Y AJUSTES 4 ESPECIFICACIONES 8 AP NDICE TABLA DE EFECTO DIGITAL 1 APLICACI N 2 DIMENSIONES 3 CONTENIDO Manual del Usuario Phonic se reserva el derecho de mejorar o alterar...

Страница 16: ...English Espa ol...

Страница 17: ...s procesadores de se al externos Dos retornos AUX est reo para incorporar las se ales exter nas en la mezcla AUX RETORNO AUX a AUX 1 para control vers til EFX Filtro de corte bajo75Hz en los canales m...

Страница 18: ...espondiente y seleccione la opci n USB Audio Codec en las preferencias del dispositivo 7 Aseg rese de ajustar bien la configuraci n del b fer a 64 de muestras para evitar los clics y pops Grabador Rep...

Страница 19: ...controles de Retorno AUX en la cara de la mezcladora Cuando se conecta un dispositivo monoaural para el Retorno AUX 1 y 2 entradas basta con conectar una de 1 4 jack a la izquierda mono y la se al ap...

Страница 20: ...n bater as para ser utilizados en estos canales Activaci n de la alimentaci n fantasma ser acompa ada por un LED iluminado encima del medidor de nivel del canal izquierdo Antes de encender la Fuente F...

Страница 21: ...ganancia del canal para que se encienda el indicador PEAK en intervalos de s lo en todo caso Esto asegurar un mayor rango din mico de audio 26 Nivel De Control Este fader de 60mm alterar el nivel de s...

Страница 22: ...LES 33 PROGRAMA DE CONTROL Este control permitir a los usuarios seleccionar uno de los 16 efectos integrados digitales de la mezcladora AM Los nombres de efecto que se corresponden con los n meros se...

Страница 23: ...or De Nivel El est reo de AM 11 segmento del medidor de nivel le da una indicaci n precisa de cuando los niveles de audio de la MAIN L R Salida de alcanzar ciertos niveles Se sugiere para el uso m xim...

Страница 24: ...Main L R Nivel De Control 60 mm fader 60 mm fader Medidor De Nivel 11 segment 11 segment Alimentaci n Fantasma 48V DC 48V DC Respuesta De Frecuencia Entrada Mic A Cualquier Salida 20Hz 60Khz 0 1 dB 0...

Страница 25: ...1 1 K ohms 1 1 K ohms Igualdad 3 band 15dB 3 band 15dB Low EQ 80Hz 80Hz Mid EQ 2 5 kHz 2 5 kHz Alto EQ 12 kHz 12 kHz Filtro De Corte De Graves 75 Hz 18 dB oct 75 Hz 18 dB oct USB Audio Stereo In Out T...

Страница 26: ...idencia de la fecha de compra Va a necesitar este comprobante para cualquier servicio de garant a No se aceptar n reparaciones o devoluciones sin un n mero RMA apropiado return merchandise autorizatio...

Страница 27: ...b Time S 0 8 to 8 8 0 4 to 0 8 16 Spring LFO 0 16 to 1 33 Numero de Programa Nombre de Programa Par metro Rango de Par metro 1 Small Hall Tiempo de Reverberaci n S 0 3 a 1 1 2 Mid Room Tiempo de Rever...

Страница 28: ...N ACTIVE MONITORS MONITORES ATIVOS COMPUTADORA PORT TIL AFOH SPEAKERS CAJAS AC STICAS AMPLIFICADOR FOOTSWITCH INTERRUPTOR DE PEDAL AUDIOFONO MICROPHONES MICR FONOS GUITAR EFFECTS EFECTOS DE GUITARRA C...

Страница 29: ...pendix Ap ndice 3 AM1204FX AM1204FX USBR DIMENSIONS DIMENSIONES 235 9 3 271 10 7 105 4 1 88 3 5 340 13 8 245 9 6 All measurements are shown in mm inches Todas las medidas est n mostradas en mm pulgada...

Страница 30: ...Appendix Ap ndice 4 AM1204FX AM1204FX USBR NOTES...

Страница 31: ...Appendix Ap ndice 5 AM1204FX AM1204FX USBR NOTES...

Страница 32: ......

Отзывы: