3.3 Ducting
A detachable rectangular duct ring is supplied to allow 0”
round lay-flat duct to be attached to the Phoenix Solution
outlet. Lay-flat plastic ducting is available. See accessories
table section 6. To attach ducting to a ring, put the plastic
duct end through the ring center and roll the duct end
outward so that it overlaps the outside of the ring. The
duct and ring may then be quickly attached to the Phoenix
Solution by snapping the ring over the three screws at the
blower outlet.
3.4 Condensate Removal
In applications where the temperature of the secondary
air stream is significantly below the dew point of the
primary air stream, condensation may occur inside the
Solution’s heat exchanger. A drip pan underneath the heat
exchanger, along with the mounting bracket secured in
the dehumidifier, direct condensate into the dehumidifier’s
drain pan for removal.
Figure 1: Bracket installed in Phoenix HT using existing fasteners.
Note tabs bent down between plastic heat exchanger panels. 200
MAX installation is similar
Figure 2: The front of the Solution has four slots to engage the
tabs on the dehumidifier bracket. The top two slots are for use
when installing on a Phoenix 200 HT and the bottom two are for
use on a Phoenix 200 MAX.
Figure 3: Solution slides forwards and engages clips on side of
dehumidifier.