Operating notes
ACCUCONTROL
32
59245(e)
7.5
Charging the ACCU AC 4.5 and ACCU AC 4.5DC
The ACCU AC 4.5 and the ACCU AC 4.5DC are charged with the PLUG-IN CHARGER PB 4.5.
Charging can be carried out as follows:
Charging directly
on the ACCU
(Figure 17,
page 35)
Charging with the
charging station
(Figure 20,
page 38)
Charging at the end product
(Figure 21, page 39)
Adapter cable
Y-cable
ACCU AC 4.5
X
X
ACCU AC 4.5DC
X
X
X
X
NOTICE
Use the PLUG-IN CHARGER PB 4.5 to charge the ACCU. They have been verified to
work properly together.
Note the following information when charging:
•
Charge the ACCU completely (for at least 10 hours) before first use. The built-in
batteries achieve their full capacity only after 5 to 10 discharge cycles.
•
The ACCU's ventilation holes should
not
be covered during the charging (see
B
in
Figure 15).
•
The ACCU should not rest upside down while charging (see Figure 18 on page 36).
•
Allow the ACCU to rest for about 1 hour after charging it; this will prolong its life-
span.
•
Depending on your model, the battery charge status is displayed on either the
handset or on the
ACCUCONTROL
control unit.