Monitoring
This function enables the monitoring of a connected MACX MCR device and is only
available in online mode.
Figure 2-2
Tab: Monitoring
Selection:
Measurement signal
–
For the MACX MCR-EX-SL-TC...
Temperature, Temperature of Cold Junction, Output Value (mA)
–
For the MACX MCR-EX-SL-RTD...
Temperature, Resistance, Sensor Current, Output Value (mA)
Selection: Representation
The values can be represented as curves ("Strip Chart") or in table form ("Value List").
Selection: Record
Selection: Time interval
A recorded measurement curve can be stored as a text file on a data carrier
("Record" checkbox) and later imported into Microsoft Excel. The following time intervals
are available as scanning rates for the sequence of measurements:
0.5 s, 1.0 s, 5.0 s, 10.0 s, 30.0 s, 1 min., and 5 min.
The operating system time is used as the time base.
Storage location
The storage location for the measured value file can be specified under "File...".
Once 32,000 measured values have been recorded, the file is closed and a new file is
opened with an additional index in the file name.
Start/stop measurement
Measurement is started by clicking on "Start" and stopped by clicking on "Stop".
Selection: Measurement signal
Selection:
Time interval
Start/stop measurement
Storage location
Selection: Record
Selection: Representation