background image

ILB BT ADIO MUX...

   

   

   

  

   

   

   

   

   

  

   

 Prelimi

n

ary 

   

   

   

   

  

   

   

   

   

   

  

   

   

   

   

  

   

   

Prel

iminary  

   

   

   

   

  

   

  

    

   

  

   

   

   

   

   

  

   

  Preli

m

inary   

   

   

   

  

   

   

   

   

   

  

   

   

   

   

   

  

   

Prel

iminary

7173_en_11

PHOENIX CONTACT

13 / 18

8

Basic circuit diagram

Figure 4

Basic circuit diagram

9

Connection example

The numbers above the device identify the connector slots.

Figure 5

Connection example

IN

OUT

OUT

Analog

Digital

24 V DC

3,3 V DC

24 V DC

15 V DC

μC

IN

U

L

U

A

1

2

3

4

5

6

7

OUT 4

IN 6

24V

OUT

A

OUT

B

IN

C

IN

D

-

U

A

+

-

U

L

+

A

Actuator at the voltage output (channel

 

1)

B

Actuator at the current output (channel

 

2)

C

Active sensor with current output (channel

 

1)

D

Active sensor with voltage output (channel

 

2)

Содержание ILB BT ADIO MUX

Страница 1: ...industrial conditions It is reliable robust and easy to handle Features Easy startup plug and play Bar graph for wireless diagnostics Range of up to 400 m outdoors 16 digital inputs 16 digital outputs Diagnostic and status indicators 2 analog single ended signal inputs for the connection of either voltage or current signals 2 analog single ended signal outputs for the connection of either voltage ...

Страница 2: ...5 1 Intended use 9 5 2 Installation notes 9 5 3 FCC approval 10 5 4 Approval for Japan 10 6 Local diagnostic and status indicators 11 7 Connect supply actuators and sensors 11 7 1 Terminal point assignment 12 8 Basic circuit diagram 13 9 Connection example 13 10 Assignment of terminal points to the remote station 14 11 Antennas 15 11 1 Omnidirectional antennas 15 11 2 Range 18 11 3 Typical combina...

Страница 3: ...k width 6 2 mm ZBF 6 SO CMS 0808778 1 Flat zack marker sheet white for terminal block width 6 2 mm ZBFM 6 SO CMS 0803650 1 Flat zack marker sheet Sheet white unlabeled can be labeled with CMS P1 PLOTTER PLOTMARK Mounting type Snap into flat marker groove for terminal block width 6 2 mm Lettering field 5 x 5 5 mm ZBFM 6 WH UNBEDRUCKT 0803618 10 Quick mounting end clamp for NS 35 7 5 DIN rail or NS ...

Страница 4: ...N 0 5 2903263 1 Antenna cable 1 m in length N male RSMA male impedance 50 ohms RAD PIG RSMA N 1 2903264 1 Antenna cable 2 m in length N male RSMA male impedance 50 ohms RAD PIG RSMA N 2 2903265 1 Antenna cable 3 m in length N male RSMA male impedance 50 ohms RAD PIG RSMA N 3 2903266 1 Antenna cable 5 m in length N male RSMA male impedance 50 ohms RAD PIG RSMA N 5 2702140 1 Attachment plug with Lam...

Страница 5: ...19 3 2903182 1 Accessories Type Order No Pcs Pkt 4 Technical data Dimensions Dimensions W H D 95 mm 123 4 mm 57 mm 95 123 4 58 5 General data Overvoltage category II Degree of protection IP20 Protection class III Degree of pollution 2 Housing material PA 6 6 FR Weight 274 g Vibration resistance in acc with EN 60068 2 6 IEC 60068 2 6 5g Shock in acc with EN 60068 2 27 IEC 60068 2 27 25g 11 ms perio...

Страница 6: ...onnection method Spring cage connection Connection method 1 wire Input voltage range 0 signal 5 V Input voltage range 1 signal 15 V Common potentials Ground Nominal input voltage UIN 24 V DC Typical input current per channel 2 3 mA Permissible conductor length to the sensor 100 m Use of AC sensors AC sensors in the voltage range UIN are limited in application according to the input design Digital ...

Страница 7: ...sistance current input 110 Ω Shunt Voltage input signal 0 V 10 V Input resistance of voltage input 150 kΩ Type of protection Suppressor diodes in the analog inputs current limitation via internal protective circuit Analog outputs Number of outputs 2 DAC resolution 12 Bit Current output signal 0 mA 20 mA Load output load current output 500 Ω Voltage output signal 0 V 10 V Load output load voltage o...

Страница 8: ...28 Noise immunity according to EN 61000 6 2 Noise emission according to EN 61000 6 4 Health according to EN 50385 Electrical safety according to EN 60950 1 Limitation of simultaneity derating No limitation of simultaneity Derating of outputs Ambient temperature TA Total current Itot 25 C 50 C 8 A 50 C 60 C 8 A TA 50 C x 0 2 A C 10 8 4 2 0 I A TOT T C A 25 10 20 30 40 50 60 70 6 Tolerance of analog...

Страница 9: ... device yourself replace it with an equivalent device Repairs may only be carried out by the manufacturer The manufacturer is not liable for damage resulting from violation The IP20 protection IEC 60529 EN 60529 of the device is intended for use in a clean and dry environment The device must not be subject to mechanical strain and or thermal loads which exceed the limits described The device compl...

Страница 10: ...his transmitter must not be co located or operating in conjunction with any other antenna or transmitter Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment 5 4 Approval for Japan NOTE Interference This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to p...

Страница 11: ...ts FS FS Red Wireless connection interrupted analog and digital outputs set to 0 LINK QUALITY LQ Green Link quality bit error rate 4 LEDs 0 0 05 3 LEDs 0 05 1 2 LEDs 0 1 1 7 1 LED 1 7 OFF No connection established If the error LED of a group of 16 outputs lights up e g connector 2 and 3 this indicates that a short circuit or overload is present at one or more of the outputs in this group DI16 16 D...

Страница 12: ... a total current of 8 A per terminal point Make sure that this value is not exceeded Terminal point Assignment Connector 1 PWR 1 1 2 1 24 V actuator supply 1 2 2 2 24 V communications power 1 3 2 3 GND 1 4 2 4 FE Connector 2 OUT1 Connector 3 OUT2 Connector 4 IN1 Connector 5 IN2 1 1 O1 2 1 O2 1 1 O9 2 1 O10 1 1 I1 2 1 I2 1 1 I9 2 1 I10 1 2 O3 2 2 O4 1 2 O11 2 2 O12 1 2 I3 2 2 I4 1 2 I11 2 2 I12 1 3...

Страница 13: ...ers above the device identify the connector slots Figure 5 Connection example IN OUT OUT Analog Digital 24 V DC 3 3 V DC 24 V DC 15 V DC μC IN UL UA 1 2 3 4 5 6 7 OUT 4 IN 6 24V OUT A OUT B IN C IN D UA UL A Actuator at the voltage output channel 1 B Actuator at the current output channel 2 C Active sensor with current output channel 1 D Active sensor with voltage output channel 2 ...

Страница 14: ... 3 1 4 2 4 LED 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Slave Slot 4 IN 5 IN Terminal point 1 1 2 1 1 2 2 2 1 3 2 3 1 4 2 4 1 1 2 1 1 2 2 2 1 3 2 3 1 4 2 4 LED 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Master Slot 2 OUT 3 OUT Terminal point 1 1 2 1 1 2 2 2 1 3 2 3 1 4 2 4 1 1 2 1 1 2 2 2 1 3 2 3 1 4 2 4 LED 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Master Slot Connector 7 Analog IN Terminal point 1 1 2 1 1 2 2 2 Slave Slot Co...

Страница 15: ...he transmitter and receiver may change e g in moving applications In applications with no line of sight because the signal then travels from the transmitter to the receiver via reflections Assembly Choose a location that provides a clear signal path in the direction of the partner antenna The ideal installation location is the top of a mast or on a control cabinet This ensures that the antenna has...

Страница 16: ...ets Figure 12 Wall mounting RAD ISM 2400 ANT OMNI 2 1 RSMA omnidirectional antenna supplied as standard Order No 2701362 Temperature range 20 C 65 C Degree of protection IP65 Impedance 50 Ω Gain 2 dBi Cable length 1 5 m Connection RSMA male Horizontal vertical apex angle 360 75 VSWR 2 90 60 30 0 120 150 180 150 120 90 60 30 0 30 90 60 30 0 120 150 180 150 120 90 60 30 0 30 ...

Страница 17: ...DIO MUX Preliminary Preliminary Preliminary Preliminary 7173_en_11 PHOENIX CONTACT 17 18 Mounting on the control cabinet Figure 13 Control cabinet feed through Figure 14 Mounting on the control cabinet Ø10 82 5 ...

Страница 18: ...a cable the shorter the cable the lower the attenuation Antenna used Mounting location Line of sight Adherence to the Fresnel zone In order to minimize signal losses keep the antenna cable as short as possible 11 3 Typical combinations of antennas and adapter cables Figure 15 Omnidirectional antenna 2 dBi supplied as standard Figure 16 Directional antenna 9 dBi with surge protection Antenna Gain R...

Отзывы: