Product description
108928_en_02
PHOENIX CONTACT
15 / 84
3.5
Safe digital inputs
Assignment
The Smart Element has safe digital inputs which can be used as follows:
– For 2-channel assignment: four 2-channel inputs
– For 1-channel assignment: eight 1-channel inputs
Technical data
See
“Safe digital inputs” on page 77
.
Parameterization
The safe digital inputs of the Smart Element can be parameterized in pairs. This means that
the inputs can be adapted to various operating conditions and different safety integrity levels
can be implemented (SIL, SILCL, Cat., PL).
The achievable safety integrity level (SIL, SILCL, Cat., PL) and error detection depends on
the following:
– Parameterization
– Structure of the sensor
– Cable installation
See
“Parameterization of the safe inputs” on page 38
See
“Connection examples of safe inputs” on page 45
.