FL SWITCH 1708 M12 POE
20
PHOENIX CONTACT
105648_en_01
Example 2:
Power consumption at ports 3 - 7 increased to 30 W each:
200 W
Power consumption at port 1 increased to 26 W:
201 W
PD at port 7 is disconnected by the PSE system,
the LED at port 7 flashes twice every 2 s
FAIL LED:
On
Relay:
Open
Total power falls to 171 W, but
all PoE LEDs are still active
Figure 3-2
Example 2 of the display behavior
PD7 has since been removed, the FAIL LED and relay have been reset by a “High” signal at
the DI.