Startup and function
105648_en_01
PHOENIX CONTACT
19
3.3.2
Schematic view of the system and display behavior in the
event of overload
Example 1:
Power reserve:
200 W
Start of safety margin (200 W - 15%):
170 W
PD power consumption on system start
7 x PoE+ with 25 W each:
175 W
Number of active LEDs:
5
FAIL LED:
Off
Relay:
Closed
Figure 3-1
Example 1 of the display behavior
25W
PD4
25W
PD3
25W
PD2
25W
PD1
25W
PD6
25W
PD5
25W
PD7
Rel
ai
s
Содержание 1708 M12 POE