Components
4083_en_A
PHOENIX CONTACT
3
Components
3.1
Switch base
The switch base FL
SWITCH EP74… installs in a standard 19-inch rack using 1U vertical
space with an additional unit (or 44 mm) of space required for cooling above and below the
switch.
CON
SOLE
MGM
T
PS2
PS
2
PS
1
RESET
1
2
SD C
ARD
PS1
ALARM
SD
1
LCD screen
2
SD port cover
3
SD port
4
Management and console ports
5
USB port
6
Power status LEDs
7
Alarm LED
8
Power supply modules
1
2
3
4
5
6
7
8
Figure
3-1
FL
SWITCH EP74… view from front
Heat generated by the switch is channeled outwards from the enclosure. For improved con-
vectional airflow, make sure there is at least one rack unit (1U) or 44 mm of space around
all sides of the device or between the devices on the rack.
Forced airflow is not required. However, any increase in airflow will result in a reduction of
ambient temperature and improve the long-term reliability of the equipment mounted in the
rack space.
The color LCD displays switch revision information and port status.
The SecureDigital (SD) port cover covers the following:
–
SD card slot #1 (top) is for factory use and is disabled.
–
SD card slot #2 (bottom) is available for storing up to 32 GB of Syslog event files.
–
The management port, a 10/100 Base-T Ethernet port, that is used as an out-of-band
factory service port. It is disabled by default and not available for user access.
–
Power status LEDs indicate the status of the installed power supply modules.
Содержание 1144175
Страница 1: ...User manual UM EN FL SWITCH EP74 HDWE Hardware and installation for FL SWITCH EP74...
Страница 24: ...FL SWITCH EP74 24 40 PHOENIX CONTACT 4083_en_A...
Страница 34: ...FL SWITCH EP74 34 40 PHOENIX CONTACT 4083_en_A...
Страница 36: ...FL SWITCH EP74 36 40 PHOENIX CONTACT 4083_en_A...
Страница 38: ...FL SWITCH EP74 38 40 PHOENIX CONTACT 4083_en_A...