Installation Instructions
Before you Begin
The controller and battery must be installed in the same room.
The controller warms up during operation; be sure it is installed on a non-flammable
surface.
Connect the Controller
Please verify that all the cable/wire connections are made properly and well insulated
so that no water or humidity can get in. This avoids any bad or loose connections that
would result in excessive heating or further damage.
1. *Connect the battery to the charge controller; Positive
(+) & Negative (-).
2. Connect the solar modules to the charge controller;
Positive (+) & Negative (-).
3. Connect the load to the charge controller; Positive (+)
& Negative (-).
*Phocos strongly recommends installing an inline fuse as
close to the battery terminal as possible.
See illustrated steps on opposite page.
Batteries fuse: use a fast acting fuse with a minimum of 1000A interrupting rating on
the battery side. We recommend to use fast acting melting fuses (e.g. car type fuses)
on the battery side, as close as possible to the battery terminal with 1.5 times the
current rating of the maximum nominal current (see table).
Fuse ratings:
Type
ECO-N-10-T
ECO-N-20-T
Fuse
30A
60A