11
Mounting the controller
Since the charge controller must be able to sense the battery temperature it must be
mounted into the same compartment together with the battery. It shall be mounted
as close as possible to battery. We recommend not to use more than 1m wire length
between battery and charge controller. This apparatus is suitable for use in Class 1,
Division 2 groups A, B, C, D or unclassified locations.
• Vertical mounting on non flammable surface with minimum 2 cm distance below and
above unit
• In case of higher ambient temperatures and limited heat dissipation (e.g. by
surrounding compartment or smaller mounting distances), charge controller will limit
its charge current to reduce temperature.
• If heat dissipation is limited by surrounding compartment, unit will limit charge current
to reuce temperature.
• The charge controller is not intended to be installed within the wiring compartment of
a PV module.
• The wiring methods in accordance with the National Electrical Code, ANSI/NFPA 70
are to be used.