background image

PHNIX  

Swimming Pool Heat Pump   

    Technical Manual 

 

 

 

 

 

PHNIX reserves the right to discontinue, or change at any time, specifications or designs 
without notices and without incurring obligations. 

 

Содержание PASRW015

Страница 1: ...PHNIX Swimming Pool Heat Pump Technical Manual PHNIX reserves the right to discontinue or change at any time specifications or designs without notices and without incurring obligations...

Страница 2: ...ydrostatic testing MPA Section 3 Installation 16 8 Installation notice 16 9 Deposition and transportation 18 10 Inspecting and Handling the Unit 18 11 Unpacking 18 12 Installation information 19 13 Hy...

Страница 3: ...you are installing swimming pool heat pump connecting water circulation and wiring electric or electronic devices please strictly operate on this manual After finishing installation and checking then...

Страница 4: ...r Input unit 1 10 HP Power 220VAC 3P 60Hz Design Code Outdoor Unit P Swimming Pool Heat Pump Three Phase Sources U Condenser Type S 1 2 3 4 5 6 8 9 10 11 PHNIX Product ENERGY SOURCING HEATING MEDIUM U...

Страница 5: ...modynamics For this reason the heat pump must raise the temperature of the thermal energy extracted from the environment using high grade energy to a level suitable for heating Heat pump work like a r...

Страница 6: ...mote control the unit Ambient temperature compensation optional The set point of the swimming pool heat pump can adjust automatic depend on ambient temperature Key 1 Temperature 2 Time 3 External temp...

Страница 7: ...150 150 150 Fan rotation speed RPM 850 850 850 850 850 Air flow direction Horizontal Horizontal Horizontal Horizontal Horizontal Noise dB A 51 54 56 56 56 Water connection mm 50 50 50 50 50 Water flow...

Страница 8: ...7 5 3 1 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 Ambient temp cop Heating capacity power input kW Inlet Water temp 24 Inlet Water temp 26 Inlet Water temp 30 The QH curve for swimming pool 1 5P 0 0...

Страница 9: ...5 3 1 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 Ambient temp Heating capacity power input kW Inlet water temp 24 Inlet water temp 26 Inlet water temp 30 The QH curve for swimming pool 2P 0 0 2 0 4 0...

Страница 10: ...1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 Ambient temp Heating capacity power input kW Inlet water temp 24 Inlet water temp 26 Inlet water temp 30 The QH curve for swimming pool 3P 0 0 2 0 4 0 6 0 8...

Страница 11: ...3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 Ambient temp Heating capacity power input kW Inlet water temp 24 Inlet water temp 26 Inlet water temp 30 The QH curve for swimming pool 3 5P 0 0 2 0 4 0 6 0 8...

Страница 12: ...7 5 3 1 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 Ambient temp Heating capacity power input kW Inlet water temp 24 Inlet water temp 26 Inlet water temp 30 The QH curve for swimming pool 4P 0 0 5 0 1...

Страница 13: ...0 7 5 3 1 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 Ambient temp Heating capacity power input kW Inlet water temp 24 Inlet water temp 26 Inlet water temp 30 The QH curve for swimming pool 4P 0 0 5 0...

Страница 14: ...Swimming pool heat pump 13 Dimension Model PASRW015 Model PASRW020 030 040...

Страница 15: ...Swimming pool heat pump 14 Model PASRW050S 060S...

Страница 16: ...tanium pipe inside of heat exchange for resist corrosion c Double coils inside for high efficiency d Low water pressure drop Items Specification Titanium pipe Outer shell Resistance water pressure 4 5...

Страница 17: ...MEANING It means prohibition and the forbidden contents are shown by graphics or words around It means compulsory execution and the forbidden contents are shown by graphics or words around It means no...

Страница 18: ...d probably occur Absolutely no mending by user himself or this will probably lead to electric shock and fire Ask your supplier for the repair and maintenance Incomplete repair and maintenance may resu...

Страница 19: ...figuration is possible With this type of handling care must be taken that the max Permissible inclination angle of 60 degree is not exceeded 10 Inspecting and Handling the Unit After delivery the pack...

Страница 20: ...ere the power voltage fluctuates seriously Place where strong electromagnetic waves exist Place where flammable gases or materials exist Place where acid or alkali gases evaporate Other special enviro...

Страница 21: ...Swimming pool heat pump 20 13 Hydraulic system Installation sketch map...

Страница 22: ...the oil or smear at the PVC end must be cleared by dry cloth with acetone if there is any Make a try to insert one pipe into another one and check the depth and fitness Mark at the pipe and then brus...

Страница 23: ...perate or become damaged Do not allow wiring to touch the refrigerant tubing compressor or any moving parts of the fan Unauthorized changes in the internal wiring can be very dangerous The manufacture...

Страница 24: ...1 2 C1 KM1 CC OUT1 OUT2 OUT3 OUT4 AC N GND T5 GND GND GND T2 PC1000 OUT5 GND T1 T4 T3 FS HP LP t 5K t 5K t 5K t 5K 4V KM1 N 1 3 2 4 5 6 7 8 01 N TC 12V 6 8K AT Ambient temperature COMP Compressor CT...

Страница 25: ...Swimming pool heat pump 24 Model PASRW040 P Model PASRW050 060S U P...

Страница 26: ...er AT Ambient temperature COMP Compressor CT Coil temperature FM Fan motor IT Inlet water temperature LP Low pressure protection OT Outlet water temperature 4V 4 way valve FS Flow switch HP High press...

Страница 27: ...06 AI 05 AI 04 AI 03 AI 02 AI 01 5V DI 01 NET 12V DI DO 2 DI DO 1 AI 11 50 GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND CN5 CN1 AI 10 GND...

Страница 28: ...controller the outlet temperature will be higher than the inlet water temperature by 1 2 5 When the unit runs for 1 hour we can feel that the water temp in the pool goes higher If the ambient temperat...

Страница 29: ...Swimming pool heat pump 28 System diagrams...

Страница 30: ...ey to switch on or off hold on 0 5 s Up key a Select higher item inside programming environment b Increase parameter value Down key a Select lower item inside programming environment b Decrease parame...

Страница 31: ...tion Symbol Explanation A Water outlet I Electrical heater reserved B Lock J Timer on off C Water inlet K Clock D Temperature setting L Fahrenheit E Water inlet temperature M Minute F Cooling N Flow G...

Страница 32: ...key for 0 5 seconds to shut it down b Mode selection The unit has three operation modes Cooling mode Heating mode Auto heat pump mode When parameter H01 0 there is only cooling mode to choose When pa...

Страница 33: ...rs setting and back to the main interface d Parameter Setting The parameters are divided into 2 different types according to their level of access by the user password and their function Factory param...

Страница 34: ...eter Setting Attention 1 The other steps are the same with parameter d01 2 Press on off twice can exit parameter interface 3 If there is no operation in 20 seconds the system will remember the previou...

Страница 35: ...er Setting Attention 1 The other steps are the same with parameter d01 2 Press on off twice can exit parameter interface 3 If there is no operation in 20 seconds the system will remember the Previous...

Страница 36: ...k In on off interface press on off for 5 seconds the keyboard will be locked When the keyboard is locked press lock for 5 seconds the keyboard will be unlocked Attention When the unit is in alarming s...

Страница 37: ...1 Press clock can save clock setting parameter and back to main Interface 2 Press on off can not save setting parameter and back to main interface 3 If there is no operation for 5s system will rememb...

Страница 38: ...the final step OFF will flash you can press clock to go on to set the timer off b If you only want to set the timer on then after the final step just press on off to back to main interface c If there...

Страница 39: ...off flashing you can set the timer off B After the last step of timer on press clock can get into timer off setting interface C If there is no operation for 5s system will remember clock setting and b...

Страница 40: ...Swimming pool heat pump 39 The operation of canceling timer on off Attention If there is only timer off for system press clock for 4s and OFF flashing then press on off key to cancel timer off...

Страница 41: ...nter parameter setting interface as following 2 Upload Press UP for 2s Download Tap DOWN During upload download process the dash will flashing When it has been done system enter next interface 3 Waiti...

Страница 42: ...temp sensor 1 failure Temp Sensor is broken Check or change it E01 High pressure protection HP HP switch is broken Check or change it E02 Low pressure protection LP LP switch is broken Check or chang...

Страница 43: ...speed fan mode Heating F05 15 60 F 16 Coil temp in low speed fan mode Heating F06 15 60 F 17 Coil temp when the fan stop Heating F07 15 60 F 18 Fan start low speed running time F08 0 23h F 19 Fan stop...

Страница 44: ...d even if the defrost hasn t finished 34 Heating stop differential r07 0 10 F 35 Minimum set point in Cooling r08 30 r09 F 36 Maximum Cooling set point r09 r08 80 F 37 r Minimum Heating set point r10...

Страница 45: ...high during defrosting then unit will be shut off and show this malfunction After recovering it system goes on defrosting 6 Temperature difference between inlet and outlet during defrosting then unit...

Страница 46: ...g F04 Coil or ambient temperature set point for the fan stop Cooling This represents the temperature in reference to F03 below which the fans are stopped F05 Coil or ambient temperature set point for...

Страница 47: ...lay after the compressor has stopped P01 2 water pump will be started and stopped at regular intervals after compressor stop Depend on P02 and P03 P02 Minimum off time before the next pump start P03 m...

Страница 48: ...R09 Max Cooling set point Establishes the maximum limit for setting the Cooling set point R10 Min Heating set point Establishes the minimum limit for setting the Heating set point R11 Max Heating set...

Страница 49: ...Swimming pool heat pump 48...

Страница 50: ...8 0 4 4566 72 0 1 0100 15 0 29 0286 29 0 4 2909 73 0 0 9800 14 0 27 6216 30 0 4 1323 74 0 0 9509 13 0 26 2913 31 0 3 9804 75 0 0 9228 12 0 25 0330 32 0 3 8349 76 0 0 8957 11 0 23 8424 33 0 3 6955 77 0...

Страница 51: ...0 8 8008 55 0 1 7232 99 0 0 4658 12 0 8 4385 56 0 1 6680 100 0 0 4533 13 0 8 0934 57 0 1 6149 1 When there is some malfunction test resistance value by multimeter and compare the practical temperature...

Страница 52: ...Swimming pool heat pump 51 PHNIX Guang Dong PHNIX eco energy solution Ltd...