background image

tray slightly downwards (2) to make its hooks slip 

into the slots.

 10 

 Place one or two cups on the cup tray.

Tip: The cups you use should have a capacity of at least 

150ml. Do not use cups that are too large, as they cause the 

coffee to get cold more quickly.

 11 

 Press the 1-cup button 

q

 if you want to brew 1 

cup. Press the 2-cup button 

qq

 if you want to 

brew 2 cups.  (Fig. 18)

The SENSEO

®

 coffee machine starts brewing. The 

machine automatically supplies the optimal amount 

of water. 

Note: You can interrupt the brewing process at any time by 

pressing the on/off button 

3

. If you switch the machine 

back on after having interrupted the brewing process, the 

machine does not complete the interrupted brewing cycle. 

Do not remove the water reservoir during a brewing 

cycle, as this causes the machine to draw in air. When 

this happens, the machine only partly fills the next cup.

 12 

 Lift the pod holder out of the machine and 

remove the coffee pod or pods.

Note: Be careful when you do this, for there may still be 

some hot water or coffee on the coffee pod or pods.

Tips

To make sure the coffee always tastes optimally, rinse 

the pod holders, the coffee collector and the coffee 

spout regularly.

The SENSEO

®

 coffee tastes best if you stir it before 

you drink it. 

If you intend to make another cup of SENSEO

®

 

coffee later, just leave the coffee machine switched 

on. The machine automatically switches itself off after 

30 minutes.  (Fig. 19)

Cleaning

Never immerse the SENSEO

®

 coffee machine in water. 

Never use scouring pads, abrasive cleaning agents or 

aggressive liquids such as petrol or acetone to clean the 

machine. 

Never clean the machine by flushing it with the lid open.

Note: All detachable parts are dishwasher-proof.

  1 

 Unplug the machine.

  2 

 Clean the outside of the machine with a soft moist 

cloth.

Remove stubborn coffee stains with vinegar diluted with 

hot water and then wipe away the vinegar residues with a 

soft cloth moistened with clean water.

  3 

 Remove the coffee spout from the 

machine.  (Fig. 20)

  4 

 Remove the coffee spout cover from the coffee 

spout (Fig. 21).

  5 

 Remove the decorative spout cover (Fig. 22).

  6 

 Remove the coffee collector (Fig. 23).

  7 

 Clean the coffee spout, the coffee spout cover, the 

decorative spout cover, the coffee collector, the 

pod holders, the cup tray and the drip tray in the 

dishwasher or in hot water with some washing-up 

liquid (Fig. 24).

Note: If you clean the cup tray by hand, always remove 

it from the machine and hold it in your hand, as it might 

prove sharp when it is handled incorrectly. Always handle it 

carefully (Fig. 25).

Note: After you have cleaned the pod holders, check if the 

sieve in the centre is clogged. If this is the case, unclog the 

sieve by rinsing the pod holders under a running tap. Use a 

washing-up brush to clean the sieve, if necessary (Fig. 26).

  8 

 Clean the water reservoir in hot water, if necessary 

with some washing-up liquid. You can also clean the 

water reservoir in the dishwasher.  (Fig. 27)

Note: If you use a washing-up brush, be careful not to 

damage the valve in the bottom of the water tank.

Tip: You can remove the anti-splash rim of the water 

reservoir to clean the inside thoroughly.

  9 

 Do not use an object with sharp edges to clean the 

water inlet on the machine (Fig. 28).

,

-

-

-

 10 

 Rinse the parts with fresh water after cleaning and 

put them back into the machine. 

 11 

 Clean the water distribution disc with a moist 

cloth (Fig. 29).

Be careful when you do this; make sure that the rubber 

sealing ring does not get stuck under the edge of the 

water distribution disc. If it does, the coffee machine starts 

leaking.

Flushing

If you have not used the coffee machine for three days, 

flush it with fresh water before you use it again.

Flush the machine in the following way:

  1 

 Fill the water reservoir with cold water up to 

the 

MAX

 indication and put it back into the 

machine.  (Fig. 10)

  2 

 Put the 1-cup pod holder 

q

 or the 2-cup pod 

holder 

qq

 in the machine without pod or pods. 

  3 

 Put a bowl (with a capacity of at least 

1500ml) under the coffee spout to collect the 

water.  (Fig. 30)

Note: Make sure the bowl is placed stably on the drip tray 

or the foot of the machine to prevent it from wobbling or 

toppling over during the flushing cycle. You can also use 

a square or rectangular container.

  4 

 Press the on/off button 

3

 (1) and then press the 

1-cup button 

q

 and the 2-cup button 

qq

 briefly 

at the same time (2).  (Fig. 9)

The machine fills itself quickly with water from the water 

reservoir. It starts to flush immediately and switches itself 

off after the flushing cycle.

Descaling
When to descale

Descale the SENSEO

®

 coffee machine frequently! 

Preferably descale 4 to 6 times a year, but at least once 

every 3 months. Descaling takes about 1 hour. 

Why to descale

Scale builds up inside the appliance during use. It is 

essential to descale the SENSEO

®

 coffee machine at least 

every 3 months. Your reasons to descale:

It prolongs the life of your SENSEO

®

 coffee machine

It ensures maximum cup volume

It ensures maximum coffee temperature

The machine produces less sound during brewing

It prevents malfunctioning

If the descaling procedure is not performed correctly, 

scale residue remains behind in the machine. This causes 

scale to build up more quickly and may cause permanent 

and irreparable damage to the machine.

Use the correct descaling agent

Never use a descaling agent based on mineral acids such 

as sulphuric acid, hydrochloric acid, sulphamic acid and 

acetic acid (e.g. vinegar). These descaling agents may 

damage your SENSEO

®

 coffee machine.

Only citric acid-based descalers are suitable for descaling 

the SENSEO

®

 machine. This type of descaler descales the 

appliance without damaging it. For the correct amount, 

see under ‘Descaling procedure’ below. Each descaling 

mixture can be used only once. After use, the descaling 

mixture is no longer active.

We advise you to use the special SENSEO

®

 Descaler 

(HD7006). Read the instructions on the package of the 

descaler.

Note: The special SENSEO

®

 descaler can be bought in the 

shops that sell SENSEO

®

 machines or on the internet at 

www.philips.com/support

Descaling procedure

  1 

 Mix 50 grams of citric acid with 1 litre of water in 

a measuring jug. Stir until the powder is completely 

dissolved.

  2 

 Fill the water reservoir up to the MAX indication 

with the descaler mixture. Then put the water 

reservoir back into the coffee machine.  (Fig. 3)

  3 

 Press the on/off button 

3

.  (Fig. 11)

The machine is ready for use when the light in the on/off 

button lights up continuously.

  4 

 Place the 1-cup pod holder 

q

 with a used coffee 

pod in it in the coffee machine. Close the lid and 

make sure it is properly locked. 

-

-

-

-

-

Note: Always put a used coffee pod in the pod holder when 

you descale the machine. This pod serves as a ‘filter’ to 

prevent the sieve in the pod holder from getting clogged with 

scale residue. 

  5 

 Put a bowl with a capacity of at least 1500ml under 

the spout to collect the descaling mixture.  (Fig. 30)

Note: Make sure the bowl is placed stably on the drip tray 

or the foot of the machine to prevent it from wobbling or 

toppling over during descaling. You can also use a square or 

rectangular container.

  6 

 Press the 2-cup button 

qq

 and let the machine 

operate. Repeat this until the water reservoir is 

empty.  (Fig. 31)

Never interrupt the descaling process!

  7 

 Repeat steps 1 to 6. Replace the used pod with 

another used pod to filter out the scale residue.

Note: To descale properly, you have to use 2 litres of 

descaling mixture.
Note: Make sure you push down the lid lever until it snaps 

home with a click. The descaling process only starts when 

the lid is closed and the lid lever is properly locked.

  8 

 Rinse the water reservoir with tap water. Fill the 

water reservoir up to the MAX indication with tap 

water and repeat steps 3 to 6.

Note: Do not refill the water reservoir with used hot water or 

the used descaling mixture.

  9 

 Fill the water reservoir with fresh tap water up to 

the MAX indication again and repeat steps 3 to 6 

once more.

Note: Always rinse the machine by letting it empty two full 

water reservoirs.

Note: You can also rinse the machine by letting it complete 

two flushing cycles as described in ‘Flushing’ in chapter 

‘Cleaning’.

 10 

 Remove the used pad and clean the pod holder 

after descaling to prevent the sieve in the centre 

from getting clogged.

Frost-free storage

If the machine has already been used and therefore has 

been flushed with water, you may only use and store it in 

a frost-free place to prevent it from becoming damaged.

Replacement

All removable parts can be ordered from your Philips 

dealer or a Philips service centre. 

Environment

Do not throw away the machine with the normal 

household waste at the end of its life, but hand it in 

at an official collection point for recycling. By doing 

this, you help to preserve the environment (Fig. 32).

Guarantee & service

If you need service or information or if you have a 

problem, please consult the worldwide guarantee leaflet 

or visit our website: www.philips.com. You can also contact 

the Philips Consumer Care Centre in your country; they 

will be happy to help you. 

The telephone number for the United Kingdom is:  

0845 6010354 (local rate).

You find the telephone numbers for other countries in 

the worldwide guarantee leaflet. If there is no Consumer 

Care Centre in your country, go to your local Philips 

dealer.

The purchase of the Philips SENSEO

®

 coffee machine 

does not exhaust any of the rights of Sara Lee/Douwe 

Egberts or Philips under any of their patents nor does it 

confer upon the purchaser a licence under these patents.

Troubleshooting

This chapter summarises the most common problems 

you could encounter with the machine. If you are unable 

to solve the problem with the information below, see 

chapter ‘Guarantee & service’. 

-

4222.200.0182.2

3/8

Содержание Senseo HD7860

Страница 1: ...HD7860 C H I J K M N L O T G F D S U B A E Q R P 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 ...

Страница 2: ...ffee machine first The flushing cycle causes the boiler to fill with water After this the coffee machine is ready for use Flush the machine in the following way 1 Tilt the water reservoir outwards and lift it out of the machine Fig 2 2 Fill the water reservoir with cold water up to the MAX indication Fig 3 3 To put the water reservoir back into the machine tilt it slightly and insert the bottom of...

Страница 3: ...sential to descale the SENSEO coffee machine at least every 3 months Your reasons to descale It prolongs the life of your SENSEO coffee machine It ensures maximum cup volume It ensures maximum coffee temperature The machine produces less sound during brewing It prevents malfunctioning If the descaling procedure is not performed correctly scale residue remains behind in the machine This causes scal...

Страница 4: ...hine in the fridge or freezer as this does not accelerate the unlocking of the lid If problems continue to occur contact the Philips Consumer Care Centre in your country The machine produces less coffee than before Perhaps the sieve in the centre of the pod holder is clogged If it is unclog the sieve by holding the pod holder under a running tap If necessary use a washing up brush or a pin to uncl...

Страница 5: ...alker können Ihre SENSEO Kaffeemaschine beschädigen Legen Sie die SENSEO Kaffeemaschine niemals auf die Seite Achten Sie immer auch beim Transport darauf dass sie senkrecht steht Elektromagnetische Felder Diese Maschine erfüllt sämtliche Normen bezüglich elektromagnetischer Felder EMF Nach aktuellen wissenschaftlichen Erkenntnissen ist die Maschine sicher im Gebrauch sofern sie ordnungsgemäß und e...

Страница 6: ... Teile nach der Reinigung mit klarem Wasser ab und setzen Sie sie wieder in das Gerät ein 11 Reinigen Sie den Sprühkopf mit einem feuchten Tuch Abb 29 Gehen Sie dabei sehr vorsichtig vor damit der Dichtungsring nicht unter dem Rand des Sprühkopfes eingeklemmt wird Andernfalls wird die Kaffeemaschine undicht Spülen War die Kaffeemaschine über dreiTage nicht in Gebrauch lassen Sie vor dem nächsten A...

Страница 7: ... mindestens 10 C beträgt Andernfalls funktioniert das Gerät nicht ordnungsgemäß Keine Reaktion beim Drücken einerTaste Prüfen Sie ob der Netzstecker richtig in der Steckdose sitzt ob der Deckel geschlossen und derVerschlusshebel verriegelt ist Wenn der Deckel nicht geschlossen ist oder derVerschlusshebel nicht nach unten gedrückt wird bis er hörbar einrastet funktioniert das Gerät nicht Wasser tro...

Страница 8: ...feepads auch in einer dunklen Röstung erhältlich Der SENSEO Kaffee ist zu stark Wenn Sie ein milderes Aroma bevorzugen sind die SENSEO Kaffeepads auch in einer milderen Röstung erhältlich Der Kaffee ist nicht heiß genug Benutzen Sie keine zu großenTassen da der Kaffee darin schneller erkaltet Wenn SieTassen verwenden sollten diese ein Fassungsvermögen von 150 ml haben Wenn Sie einen Becher benutze...

Отзывы: