Restoring the Boiler_empty_flag to production default:
Some times it is needed that the boiler of the Senseo have to
be emptied.
This for instance in wintertime where the possibility exists
that the boiler becomes frozen during transport e.g.
For those occasions it is handy to restore the
Boiler_empty_
fl ag
again to production default in the Eeprom.
Bringing the Senseo back into production status, has the
benefi t the fl ush routine will be activated automatically when
installed by the consumer.
To
SET
the
Boiler_empty_fl ag
can be done by:
Keep the 1-cup button pressed while plugging in the power
cord of the appliance.
The main switch LED will blink very rapidly for
approximately 1 second.
To check if the
Boiler_empty_fl ag
is really set, you should
reconnect the power cord a second time to the net and push
the main switch.
The main switch LED should light continuously.
Pos
Service code
Description
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
4222 259 42510
4222 259 42520
4222 247 42550
4222 247 52650
4222 259 37910
4222 240 05940
4222 247 41860
4222 247 59790
4222 247 41950
4222 247 06810
4222 240 05990
4222 247 41920
4222 259 37900
4222 259 34970
4222 259 35470
4222 247 05320
4222 259 36900
4222 247 05130
4222 259 35500
4222 259 40100
4222 247 50890
4222 259 38540
4222 247 05180
4222 247 35870
4222 247 39890
4222 247 05110
4222 259 37240
4213 247 05250
Pad holder single
Charcoal grey
Pad holder double
Charcoal grey
Collector Black
Spout cover
Charcoal grey
Spout assy
Black
Drip tray cover
Driptray
Black
Lever Charcoal
grey
Pushrod
Sealing ring
Ejector pin
Distribution disk
Black
Service display assy
230 V Blue
3-Way valve
Boiler assy
V7.1 - 230 V
Hose
PCB assy
230 V
O-ring (NTC)
NTC assy
Water tank assy
Transparent blue
Valve outlet
Charcoal grey
Back cover
Charcoal grey
WC sealing
Filter
WC socket hard
Corrugated tube
Small pump
230 V
Foot
= changed