background image

 

 

Philips Lighting North America Corporation 
200 Franklin Square Drive 
Somerset, NJ  08873, USA 
Phone:  855-486-2216 

www.philips.com/luminaires

  

Philips Lighting Canada Ltd. 
281 Hillmount Road, 
Markham ON, Canada  L6C 2S3 
Phone:  800-668-9008 

www.philips.com/luminaires

 

9140053550 February 2016 

 

 

 

STEP 2 for Pendant Mounting  – 
Attach canopy bracket to a 3-1/2” or 4” octagonal or single gang junction box.  Screw pivot ball onto one 
end of the pendant stem.  Feed AC supply wiring thru the pendant stem and set pivot ball into canopy 
bracket (note that there is a slot on the pivot ball that matches a finger on the canopy bracket.  This detail 
prevents uncontrolled twisting of the exit sign due to breezes, impact, etc.)  Slide canopy over pendant 
stem and snap onto the canopy bracket.  Thread the jamb nut onto the end of the pendant stem followed 
by the pendant adapter.  Remove the center knockout that is found in the top of the backplate or extra 
stencil face (use the extra stencil face for double sided “EXIT” installations – single face installation using 
the backplate is shown above). Place the resulting opening in the backplate or stencil over the threaded 
nipple on the pendant adapter and thread on the jamb nut.  A four pole connector assembly is provided 
on the stencil/electronics assembly for AC service connection.  Make AC service connections according to 
the table below.  Snap stencil/electronics assembly to backplate or extra stencil and refer to operating 
instructions section. 

230VAC 

120VAC 

Green Wire - Ground 

Green Wire - Ground 

White Wire - Common  White Wire - Common 

Black Wire – Cap Off 

Black Wire – 120VAC 

Blue Wire – 230VAC 

Blue Wire – Cap Off 

Green - Ground 

CAUTION:  Unused primary wire must be capped off! 

 

Содержание SC Series

Страница 1: ...d be mounted in locations and at heights where it will not be readily subjected to tampering by unauthorized personnel The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition Do not use this equipment for other than intended use Do not use outdoors Do not let supply cords touch hot surfaces Do not mount near gas or electric heaters Use caution when servicin...

Страница 2: ...P 2 for Wall Mounting Remove keyhole knockouts for securing the backplate to the mounting surface as necessary Keyhole knockout patterns are provided for 3 1 2 and 4 octagonal boxes single gang boxes and widely spaced keyhole knockouts are provided for use with wall anchors not provided A large central knockout is provided for AC service entry or the conduit entry knockout in the upper surface of ...

Страница 3: ...emove one of the two knockouts that are found in the side or top of the backplate or extra stencil face use the extra stencil face for double sided EXIT installations single face installation using a blank backplate is shown above Place the resulting opening in the backplate or stencil over the threaded nipple on the canopy and thread on the jamb nut A four pole connector assembly is provided on t...

Страница 4: ... the canopy bracket Thread the jamb nut onto the end of the pendant stem followed by the pendant adapter Remove the center knockout that is found in the top of the backplate or extra stencil face use the extra stencil face for double sided EXIT installations single face installation using the backplate is shown above Place the resulting opening in the backplate or stencil over the threaded nipple ...

Страница 5: ...maining four Torx screws thru the corners of the stencil electronics assembly to finish the installation if vandal resistant shield option has been ordered use the Torx screws to also attach the clear shield to each stencil face Recessed Mounting Option Make a 13 7 8 x 9 1 2 cutout in the mounting surface Secure the backbox with nails or screws to the stud structure Route flex conduit into the upp...

Страница 6: ...lluminates and EXIT is illuminated 2 Press the test switch pilot lamp and verify that the pilot lamp turns off and EXIT remains illuminated 3 Leave AC connected for a minimum of 24 hours before performing any extended testing Full recharge of batteries may require one full week Notes 1 This equipment is provided with a lockout feature whereby connecting battery leads prior to energizing AC power w...

Страница 7: ...manually initiated diagnostic test Red LED indicator Single Flash battery fault Two Flashes lamp failure light bar failure EXIT signs Three Flashes charger fault Four Flashes transfer fault If more than one fault condition is present simultaneously the red LED will flash the indication pattern for each fault independently then repeat the cycle Pushbutton Test Switch Long Press longer than 0 5sec t...

Страница 8: ...ion 200 Franklin Square Drive Somerset NJ 08873 USA Phone 855 486 2216 www philips com luminaires Philips Lighting Canada Ltd 281 Hillmount Road Markham ON Canada L6C 2S3 Phone 800 668 9008 www philips com luminaires 9140053550 February 2016 ...

Отзывы: