DAS-000060-00 R04 05-18
Replacing Fuses
PDS-60ca has a fuse for each of its ports, protecting
each port from excessive
current. Always replace blown fuses with the same rated fuse:
1. Make sure that the device’s power is OFF.
2. Using a Phillips screwdriver, unscrew the six screws holding the cover in place.
3. Remove the blown fuse from its metal clips next to the luminaire and data
connection ports (see image on the right).
4. Replace the fuse with a new, identically-rated fuse.
5. Replace the cover, ensuring that the gasket is seated properly and that no wires
are pinched.
6. Attach the cover with the six included screws. Tighten screws to 8 to 10 in-lbs
(1 in-lb = 11.2985 N-cm). If you are installing in a wet or damp location, seal
with RTV silicone.
Device
Replacement Fuse
PDS-60ca 7.5 V
(2) 5 A, 5 x 20 slow blow fuses
PDS-60ca 24 V
(2) 4 A, 5 x 20 slow blow fuses
Fuse
OUT 1
OUT 2
DMX IN
DMX OUT
ETHERNET
Power
Indicators
Copyright © 2018 Philips Lighting Holding B.V. All rights reserved.
Chromacore, Chromasic, CK, the CK logo, Color Kinetics, the Color Kinetics
logo, ColorBlast, ColorBlaze, ColorBurst, ColorGraze, ColorPlay, ColorReach,
iW Reach, eW Reach, DIMand, EssentialWhite, eW, iColor, iColor Cove,
IntelliWhite, iW, iPlayer, Optibin, and Powercore are either registered trademarks
or trademarks of Philips Lighting Holding B.V. . in the United States and/or
other countries. All other brand or product names are trademarks or registered
trademarks of their respective owners. Due to continuous improvements and
innovations, specifications may change without notice.