background image

1.

Z-Wave’s Groups (Association Command Class Version 2)

The Switch can be set to send reports to associated Z-Wave devices.  It supports
one association group with one node support for Grouping 1. For group 1, the
Switch will report its latest status to Z-Wave Controller. Grouping 1 includes,
SWITCH_BINARY_REPORT, METER_REPORT, ALARM_REPORT.

2-1 Auto report to Grouping 1 (Maximum Node 5)

2-1-1 On/Off Event Report 

   When “on” or “off” state has been changed, it will send Binary Switch Report

to the node of Grouping 1. 

Binary Switch Report

ON:  

[Command Class Switch Binary, Switch Binary Report, Value

=255(0xFF)]

OFF:  

[Command Class Switch Binary, Switch Binary Report, Value

=0(0x00)]

2-1-2 Instant Power Consumption vary over 5% report
When the power consumption of load varies over 5%, it will send Meter report

to the nodes of Grouping 1.

Meter Report Command: 

[Command Class Meter

Meter Report

Rate Type = 0x01

Meter

Type = 0x01

Precision = 1

Scale = 0x02

Size = 4

Meter Value(W) ]

2-1-3 Overload alarm report
When PAN44 detects the current is more than 14.5A, it will send Alarm Report
to Group 1 node. 

The content of Alarm Report 

Alarm report command:

[Command_Class_Alarm, Alarm_Report, Alarm Type = 0x08, Alarm
Level = 0xFF]

2-2 Response to Meter Get Command

   The Switch will report its (1) instant Power Consumption (Watt) or (2) accumu-

lated power consumption (KWH) or (3) AC load Voltage (V) or (4) AC load
current (I) (5) load power factor (PF) to Z-Wave Controller after receive the
Meter Get Command from Z-Wave Controller.

2-2-1 Instant Power Consumption (Watt) of Switch

    When receiving Meter Get Command, it will report Meter Report Command to

the node.

Meter   Get   Command:  

[Command   Class   Meter,   Meter   Get,   Scale

=0x02(W)]

Meter Report Command:

[Command Class Meter

Meter Report

Rate Type = 0x01

Meter

Type = 

0x01

Precision = 1

Scale = 0x02

Size = 4

Meter Value(W) ]

 Example:

Meter Value 1 = 0x00 (W)
Meter Value 2 = 0x00 (W)
Meter Value 3 = 0x03 (W)
Meter Value 4 = 0xEA (W)
Meter(W) = Meter Value 3 *256 + Meter Value 4 = 100.2W

2-2-2 Accumulated Power Consumption (KWh)

When receiving Meter Get Command, it will report Meter Report Command to

the node.

Meter Get Command: 

[Command Class Meter, Meter Get, Scale = 0x00 KWh)]

Meter Report Command:

[Command Class Meter

Meter Report

Rate Type = 0x01

 

Meter

Type = 0x01

 Precision = 2

Scale = 0x00

Size = 4

Meter Value (KWh)]

Содержание PAN44

Страница 1: ... unplug and reconnect the switch will reset its overload condition to normal status Specification Operating Voltage 100V 240V 50Hz 60Hz Maximum Load Ampere 13A Resistive load PAN44 1 PAN44 2 Range Minimum 40 m in door 100m outdoor line of sight Operating Temperature 0 C 40 C Frequency Range 908 4MHz 916 0MHz USA PAN44 1 920 927MHz Taiwan Japan PAN44 2 RF Maximum Power 10dBm Peak 10dBm Average Spec...

Страница 2: ...to toggle switch on and off or carries out inclusion exclusion reset or association When first power is applied its LED flashes on and off alternately and repeatedly at 2 second intervals It implies that it has not been assigned a node ID The table below lists an operation summary of basic Z Wave functions Please refer to the instructions for your Z WaveTM Certificated Primary Controller to access...

Страница 3: ...or 5 seconds 3 IDs are excluded LED 2s On 2s Off Enter auto inclusion Association 1 The PAN44 is an always listening Z Wave device so associations may be added or removed by a controller at any time Or If your controller re quires to have the PAN44 send a node information frame or NIF for associations then pressing the On Off button three times within 2 sec onds will cause the PAN44 to send its NI...

Страница 4: ...y press and release the On Off but ton The LED will turn OFF and the load plugged into the Switch will also turn OFF Programming 1 Basic Command Class Binary Switch Command Class The Switch will respond to BASIC and BINARY commands that are part of the Z Wave system 1 1 BASIC_GET BINARY_SWITCH_GET Upon receipt of the following commands from a Z Wave Controller the Switch will report its On Off sta...

Страница 5: ...5A it will send Alarm Report to Group 1 node The content of Alarm Report Alarm report command Command_Class_Alarm Alarm_Report Alarm Type 0x08 Alarm Level 0xFF 2 2 Response to Meter Get Command The Switch will report its 1 instant Power Consumption Watt or 2 accumu lated power consumption KWH or 3 AC load Voltage V or 4 AC load current I 5 load power factor PF to Z Wave Controller after receive th...

Страница 6: ...eter Value V Example Scale 0x04 V Precision 1 Size 2 2 Bytes of V Meter Value 1 0x09 V Meter Value 2 0x01 V AC load Voltage Meter Value 1 256 Meter Value 2 230 5 V 2 2 5 AC load current I When receiving Meter Get Command it will report Meter Report Command to the node Meter Get Command Command Class Meter Meter Get Scale 0x05 I Meter Report Command Command Class Meter Meter Report Rate Type 0x01 M...

Страница 7: ...nstant power consumption is 45 hours 5s 32767 3600 45hr When the setting is 0 PAN44 will disable Watt auto report function The default value is 720 3 2 KWH Meter Report Period If the setting is configured for 1hour set value 6 PAN44 will report its Ac cumulated Power Consumption KWh to Group1 node every 1 hour The maximum interval to report its Accumulated Power Consumption KWh is 227 55 days 10mi...

Страница 8: ...e default setting is 1 Enable Whenever PAN44 manually switch on or off it will send BINARY_SWITCH_ REPORT to the node of group1 1 Firmware update over the air OTA PAN44 is based on 700 series SoC and supports Firmware Update Command Class it can receive the updated firmware image sent by controller via the Z wave RF media It is a helpful and convenient way to improve some function if needed 2 The ...

Страница 9: ...t generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful inter ference to radio communications However there is no guarantee that interference will not occur in a particular in stallation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipme...

Отзывы: