LOCAL MENU CONTROLS
´
SET MASTER ABC
This function allows the monitor’s light sensor to operate as Master ABC Sensor for the Daisy-chained units. When enabled, the monitor sends (every
2 seconds) through the Daisy-Chain a command sequence to set “Contrast and Brightness” of all units to a suitable value, according to the mea-
sured ambient light.
Pressing the “SELECT” key, the ‘ABC Master’ function setting is toggled to ABC Master ON (if Daisy Chain is ON) or the warning blinking mes-
sage “Daisy Chain Off” (if Daisy Chain is OFF).
Note: If any other monitor was set with ABC Master “ON”, it shall be automatically turned to ABC Master “OFF”.
When replacing one unit in an existing dasy chain installation, please take care of setting the new unit the same as the replaced one, to avoid dasy
chain conflict between 2 master units.
´
POWER SAVING
This function when enabled will check the presence or absence of horizontal and vertical TTL sync signals and activate the proper Power-State
accordingly: 1) Power-On (< 190 W) if both H &V sync.s ; 2) Standby/Suspend (< 15 W) if only one sync; 3) Power-Off (< 1.5 W) if no sync sig-
nal is present.
Pressing the “SELECT” key, the active mode of this function is toggled (ON/OFF).
´
AUTO DEGAUSS
When enabled, Degaussing will be automatically triggered by the detection of a magnetic field variation (e.g. by changing or rotating the monitor unit
orientation). When disabled, degauss is executed only once at power-on.
In Daisy Chain configuration, the unit on which the function is set becomes the ‘Degauss-Master-Unit’.
This means that the specific unit will send on, the daisy chain line the Degauss Command, and all units will execute the function simultaneously.
In Daisy Chain configuration, at power on the unit whose Daisy Address is “1” and AUTO DEG. ON will execute the Degauss command on itself and
send the same command through the Daisy Chain to all other units connected. It is very important to assign an “address-1” unit in each Daisy Chain
installation in order to have the Degauss function executed on each unit at power on.
Pressing the “SELECT” key, the ‘previously active mode of this function item is toggled.
Note: When replacing one unit in an existing dasy-chain installation, please take care of setting this function, on the new unit, the same as on the
replaced one, to avoid dasy-chain conflict between two units set as AUTO DEG. ON.