Страница 1: ...Published by GE 9845 Monitor Service Dept Printed in Italy Copyright reserved Subject to modification 3119 206 13832 H GB USER MANUAL MGD203 MGD403 ...

Страница 2: ...d that any changes or modifications made to this device that are not expressly approved by the manufacturer may void the user s authority to operate the equipment Cables Connections to this device must be made with shielded signals cables with metallic RFI EMI connector hoods to maintain compliance with FCC Rules and Regulations The lighting flash with arrowhead symbol is intended to alert the use...

Страница 3: ...demarks are the sole property of their respective companies or organisation Cyberscreen monitor is a Philips technology Printed in Italy The manufacturer declares that this product satisfies the basic requirements of Electromagnetic Compatibility and Safety of the Directive 93 42 EEC Medical Device regarding risk Class I device As having been designed and tested in conformity with the requirements...

Страница 4: ...npacking 6 Connecting your monitor 7 9 INFORMATION AND USE OF THE CONTROL PANEL Control location and functions 10 HARDWARE OSD Adjustment size position geometry and special functions 11 22 Technical Specification APPENDIX 1 Mechanical Specification APPENDIX 2 Note for UK APPENDIX 3 Factory Pre Set Video Timings APPENDIX 4 ...

Страница 5: ...ormations An introduction to the product features Instructions for unpacking and connecting to a computer this allows you to quickly set up and receive the best performance from your new monitor Guide to the On Screen Display Instructions for the care and maintenance of the monitor to extend its service life Trouble shooting information in case you encounter any difficulties while you are installi...

Страница 6: ...e as well as color video cards of both Apple and PC environments and from all the high end workstations This monitor incorporates a DDC1 DDC2B function that allows bidirectional communications between the monitor and PC system for optimal video configuration It is also possible to use up to 15 of these monitors in Daisy Chain Mode as explained later in this manual Almost all the internal functions...

Страница 7: ...g Black Level Stabilization for quick warm up 4 min and perfect contrast stability over time Integrated Ambient Light Compensation control function RS 485 like Daisy chain bus connection up to 15 monitors allows simultaneous adjustment of each enabled monitor from each monitor s keyboard RS 232 serial connection to host computer or service laptop Large number of functions available through the int...

Страница 8: ...y due to the aging of the CRT Digital Brightness Uniformity thanks to the CyberScreen Technology the screen brightness can be digitally controlled all over the screen making possible to have a 90 brightness uniformity Digital Control all the monitor parameters and display functions are accessible either via the Service Software package or by means of a set of direct commands making it easy to remo...

Страница 9: ...DATA CHANNEL This feature allows your operating system and application software to retrieve the display identity information directly from the display device Note the DDC feature works only if the monitor is connected to the PC by a mini D Sub 15 pins mini D Sub 15 pins video signal cable as explained in the chapter Connecting your monitor ENVIRONMENT All the package materials are recyclable This ...

Страница 10: ...male connectors are parallel wired RS485 like Multi Point Serial Interface to allow the connection of up to 15 units in daisy chained configura tion each one having unique address in the range from 1 to 15 The maximum total cable lenght between monitors is 15 m If Daisy Chain Mode is ENABLED the RS232 KEYBOARD and ABC controls are trasmit ted to all the other monitors and at the same time executed...

Страница 11: ...ED OFF Both H V signals are inactive the power consum ption is about 3 W LED off This function can be easily disabled in a safe and permanent way through the Hardware OSD Mode Power Saver The manufacturer is a partner in the EPA s Energy Star computer program The Energy Star emblem does not represent EPA endorsement of any product or ser vice PRE SET MODES The monitor memory can store the geometry...

Страница 12: ...or only on a strong table or a desk Avoid placing your monitor on top of a computer To minimise glare and reduce eye fatigue it is recommended to place your monitor in the following positions avoid direct sunlight or other bright light source keep the screen lower than your eyes with an angle of 20 respect to the ideal horizontal line set the monitor to 1 gun mode when full brightness is not requi...

Страница 13: ...contemporary LED light turns green and the optimal Image Quality shall be restored CONNECTING YOUR MONITOR Connection to the mains Warning Important figure 1 1 Remove the connector protection from the rear cover 2 Connect the female plug of the power cord to the mainssocket on the back of the monitor see figure 1 3 Connect securely the male plug of the power cord to the AC power supply outlet All ...

Страница 14: ...V of the video cable to the socket as in 2 see figure 4 In this configuration the guns are driven inde pentently the monitor is seen as colour 4 If you use some monitors in Daisy Chain configuration the units shall be con nected each other as shown in figure 5 5 Connect the other end of the video cable to the VIDEO OUTPUT of your PC with high resolution graphic card or usual VGA graphic card Note ...

Страница 15: ...2 IN OUT DAISY CHAIN UNIT 1 UNIT 2 UNIT 6 FROM COMPUTER SYSTEM figure 5 This connector located on the back of the monitor is provided for Service maintenance of the monitor through an extra RS232 line It is to be used only by qualified personnel RS232 CONNECTOR RS 232 Caution ...

Страница 16: ...io between the brightness of the brightest and darkest parts of a picture LED COLOR MEANING TABLE OFF Monitor in STAND BY condition or powered off YELLOW BLINKING Monitor in suspend condition see POWER MANAGEMENT RED Monitor out of reference see REFERENCE SETTING STORE REFERENCE SET TING YELLOW USER SETTING Calibration mode is active GREEN One of the five ABC SENSOR 3 COLOR LED ...

Страница 17: ...__ STORE REF SET ____ H SIZE ____ V SIZE ____ H SHIFT ____ V SHIFT ____ TILT ____ ABC CONTRAST ____ ABC BRIGHTNESS ____ SERVICE MENU NOTES The DIRECT KEY ENTRY functions are transmitted over the daisy chain if enabled to set all monitors with the same light paramiters brightness and contrast The OSD MENUs are meant for SERVICE purposes only The GLOBAL MENU functions are transmitted over the daisy ...

Страница 18: ...ion is not transmitted over the daisy chain and is only executed locally All 4 buttons KEYBOARD UNLOCK Notes This function will never be locked This function is transmitted over the daisy chain when Daisy Chain Mode is enabled DIRECT KEYING FUNCTIONS REFERENCE SETTING Pressing A A Brightness AND A A Brightness together the brightness and contrast optimal factory stored values are recalled and upda...

Страница 19: ...ameter value Exit A A Brightness Escapes from the On Screen Display Menu Function Adjust B B Contrast When main menu or sub menu is active it allows to move or scroll to the previous upper item When the highlighted item is blinking decrements the relevant parameter value Adjust B B Contrast When main menu or sub menu is active it allows to move or scroll to the following lower item When the highli...

Страница 20: ...rightness mode and 1 GUN Low brightness mode If the active selection is 1 GUN Low brightness the front LED indicator is set to Red In the other input selection cases 3 BNC or D SUB this func tion is locked to 3 GUNS mode The message shown on the OSD window will be 3 GUNS Locked Pressing the SELECT key the current active mode is TOGGLED DEGAUSS When the Global Menu window is displayed locally on th...

Страница 21: ...l the other monitors connected execute the command Pressing Adj or Adj the highlight selection of menu item moves downward upward and exit from the Lock item line without activat ing any LOCK mode If Lock All or Store or Cntrl is enabled it is not allowed to activate OSD Menu anymore The warning message shall be displayed To access OSD Menu it is necessary to unlock the keyboard e g ABC MENU When ...

Страница 22: ...t setting through all of the 5 possible choices at the same time the newly selected reference becomes the active one If the Daisy Chain Mode option is enabled the proper daisy chain command sequence is transmitted over the Daisy Chain Line and all other monitors execute the same function LOCAL MENU When the Global Menu window is displayed on the screen if LOCAL MENU item is highlighted Pressing th...

Страница 23: ...function is toggled ON OFF AUTO DEGAUSS When enabled Degaussing will be automatically triggered by the detection of a magnetic field variation e g by changing or rotating the monitor unit orientation When disabled degauss is executed only once at power on In Daisy Chain configuration the unit on which the function is set becomes the Degauss Master Unit This means that the specific unit will send o...

Страница 24: ...ser Setting Store User Setting via Keyboard 1 GUN 3 GUNS DEGAUSS KEYLOCK ALL STORE CNTRL ABC FULL REDUCED OFF REF SETTING 1 2 3 4 5 ABC MASTER OFF via On Screen Display selection ABC measurement control and RS232 Commands When a unit is set to Daisy Chain OFF it shall automatically reset to ABC Master OFF to prevent the possibility to set to ABC Master ON in more than one unit in a Daisy Chain con...

Страница 25: ...ce more will remove the warning message LIGHT BAR ON OFF When disabled this function prevents the appearing on screen of Brightness Contrast Bars Ref Setting User Setting and User Store messages after touching one of control keypads When enabled the above mentioned messages appear for 3 seconds on the screen during adjust operation from keypads Pressing the SELECT key the previously active mode of...

Страница 26: ... the EXIT key at any time when the message is blinking last change in the new OSD position is only temporary saved in memory In this case if the monitor is switched OFF the temporary saved change is lost SHOW CONFIGURATION This function is intended to display monitor firmware release accumulated operating hours selected video channel Hor Vert frequencies on the screen window Pressing the SELECT ke...

Страница 27: ...ress makes the line blinking the corresponding parameter can now be modified using and keys A further SELECT key press makes the line stop blinking This way the value is also saved in memory If you press the EXIT key when the message is blinking the new parameter value remains active but is not saved in memory Pressing the EXIT key the Local Menu disappears When displaying a new timing not yet kno...

Страница 28: ...cal Menu disappears ABC BRIGHTNESS REDUCTION FACTOR EFFECT This function allows to customize the BRIGHTNESS behavior of the ABC circuit at different ambient light in the range 10 to 100 lux To modify ABC_ Brightness Reduction Factor the sequence of operations is the following First set ABC FULL in the Global Menu and than blank the sensor e g with a finger for all the time of the operation Highlig...

Страница 29: ...ghtness and contrast reduction factors please use the following sequence of operations a select one of 5 reference settings e g 1 in the OSD global menu b Set ABC contrast and ABC brightness reduction factors according your needs following the Local Menu procedures indicated above c repeat steps a and b selecting the other reference settings SERVICE MENU This function is reserved to TECHNICAL SERV...

Страница 30: ...APPENDIX ...

Страница 31: ...024 90Hz MGD 403 up to 1600x1200 75H RESOLUTION up to 1280 x 1024 90 Hz MGD203 1600x1200 75 Hz MGD403 VISUAL PERFORMANCE SPOT SIZE 0 30 mm at 120 cd m2 center typical 0 35 mm at 300 cd m2 center 0 45 mm at 750 cd m2 center EMI RFI CISPR11 EN5011 Class B FCC Class A IEC 601 1 2 EN60601 1 2 SAFETY REGULATIONS EN60950 UL1950 CSA No 950 EN601 1 UL2601 CSA No 601 1 FDA DHHS RœV MARKS AND STATEMENTS CSA...

Страница 32: ... 6 5 9 Pin N Assignment Pin N Assignment 1 NC 6 NC 2 Rx viewed from PC 7 NC 3 Tx viewed from PC 8 NC 4 NC 9 5 V 5 Ground 1 6 5 9 Pin N Assignment Pin N Assignment 1 Ground 6 NC 2 Sense line 7 Ground 3 NC 8 NC 4 NC 9 Data line 2 5 Data line 1 R V G B H BNC Assignment R Red Analog Video G Green Analog Video Combined sync on green B Blue Analog Video V Vertical sync H H V Horizontal Comp sync 5 Daisy...

Страница 33: ...APPENDIX 3 MGD 203 MECHANICAL SPECIFICATIONS CARATERISTIQUES MECANIQUES WEIGHT POIDS 24kg 52 9 lbs DIMENSIONS w x h x d l x h x p 426 x 446 x 495 mm ...

Страница 34: ...APPENDIX 4 MGD 403 MECHANICAL SPECIFICATIONS CARATERISTIQUES MECANIQUES WEIGHT POIDS 32kg 70 5 lbs DIMENSIONS w x h x d l x h x p 498 x 485 x 557 mm ...

Страница 35: ...ible shock hazard should it be inserted into a 13A socket elsewhere How to connect a plug The wires in the mains lead are colored in accordance with the following code BLUE NEUTRAL N BROWN LIVE L GREEN YELLOW EARTH GROUND E 1 The GREEN YELLOW wire must be connected to the terminal in the plug which is marked with the letter E or by the Earth symbol or colored GREEN or GREEN YELLOW 2 The BLUE wire ...

Страница 36: ...mp Sy Pol V Sy Pol H Width mm 356 380 380 380 380 356 V Height mm 285 285 285 285 285 285 Factory Preset N 1 2 3 4 5 6 DEC 77 72 SUN 72 76 ST MAC 2 SUN 62 66 SUN 71 66 ATI 80 75 ITEM Unit 1280x1024 1152x900 1152x870 1152x900 1280x1024 1280x1024 72 Hz 76 Hz 75 Hz 66 Hz 66 HZ 75 H Pixel Rate MHz 130 81 107 89 100 00 94 80 116 79 135 00 Hor Freq KHz 77 12 71 8 68 68 61 91 71 43 79 976 Vert Freq Hz 77...

Отзывы: