5. Use wire nuts to connect line, neutral, and ground.
6. Tuck wire connections into the junction box.
7. Screw the fixture’s canopy base into the junction box using the four included
10-24 stainless steel screws. If installing in a damp or wet location, seal all junction
boxes with contractor-grade RTV silicone sealant. Use gaskets, clamps, and other
parts and fittings required to comply with local outdoor wiring codes.
8. If installing in parallel, connect the wires from each fixture to the lead wire from
the line power source in the common junction box.
9. Connect the wire from the first fixture in the series to the line power source if
installing in series, or from the common junction box to the line power source if
installing in parallel.
Surface-Mounting eW Burst Powercore Architectural Fixtures
1. Prepare eW Burst Powercore Architectural fixtures for surface-mounting:
• Remove the nylon cable clamp from the fixture’s leader cable where it exits the
underside of the canopy base.
RTV Silicone
RTV Silicone
RTV Silicone
RTV Silicone