WT120C G2 EL MDU

.

Max

0 °C

Min.

25 °C

IK08

50 Hz

60 Hz

IP65

220 V
240 V

WT120C G2 LED40S/840 PSU MDU ELB3 L1200

WT120C G2 LED34S/840 PSU MDU ELB3 L1500

WT120C G2 LED60S/840 PSU MDU ELB3 L1500

kg

System light

output (Lm)

4000

3400

6000

System light

output

Emergency

mode (Lm)

GLOW
WIRE
850 °C

CoreLine
Waterproof

Printed in Hungary
Data subject to change without notice
Keep for future reference: www.philips.com/lighting

1/11

444316022542 - 01
© 08 / 2020 Signify Holding All rights reserved

A

B

C

D

E

min

E

max

F

WT120C G2 LED40S L1200

1215

538

1062

10

WT120C G2 LED34S L1500
WT120C G2 LED60S L1500

Type

Dimension (mm)

Nr. of 

clips

1362

85

12

76

1515

80

38

838

C

D

B

F

A

E min

E max

900

900

900

1,6

1,9

1,9

T

20

27

24

LIFE

L75

50K hrs

Содержание CoreLine Waterproof WT120C G2 EL MDU

Страница 1: ...cy mode Lm GLOW WIRE 850 C CoreLine Waterproof Printed in Hungary Data subject to change without notice Keep for future reference www philips com lighting 1 11 444316022542 01 08 2020 Signify Holding All rights reserved A B C D Emin Emax F WT120C G2 LED40S L1200 1215 538 1062 10 WT120C G2 LED34S L1500 WT120C G2 LED60S L1500 Type Dimension mm Nr of clips 1362 85 12 76 1515 80 38 838 C D B F A E min...

Страница 2: ...AINTAINED LINE 2Nm 27 2 N 1 45 30 8 q0 75 2 5mm O8 12mm 2b 1 PSU versions OPTIONAL ANTI VANDAL MOUNTING x 2 1Nm E u 100 Mid or side entry optional Knock out for cable entry 24 2Nm 27 Switch off the power supply before installation a c d 8 30 45 O8 12mm q0 75 2 5mm b ...

Страница 3: ...3 11 4 2Nm 27 Replacement of Silicone Plug optional New Silicone Plug a b c d Ø 12 14 mm 3 Remove protection foil after installation and before usage 6 5a 5b 2b e f g ...

Страница 4: ...abled The sensor can be set to only allow the luminaire to switch on when the ambient lux level is less than approximately 300 lux When set to DISABLE mode the daylight sensor will switch on the luminaire when motion is detected regardless of ambient light level 7 Status LED indication shown on page 8 1 2 2 8 9a Detection area default 100 Detection area can be reduced by selecting the combination ...

Страница 5: ... setting use Dip switches 3 and 4 to choose a sensitivity lower than 100 Other undesired detections can be caused by Strong electromagnetic fields heavy vibrations water running in pipes Detection area sensitivity can be reduced caused by big metal surfaces nearby or water on the ground Initialization After power on the sensor will warm up and calibrate the environment for about 120 seconds In the...

Страница 6: ...onents may be under high voltage T20 11b New driver 1 2Nm T20 Driver replacement 11c T20 11d 1 2 6 SERVICE Light source LED is non user replaceable The light source contained in this luminaire shall only be replaced by the manufacturer or his agent or a similar qualified person Do not touch electronic components Electronic components maybe under high voltage Caution risk of electric shock A T T E ...

Страница 7: ... next power up the automatic detection process will start again Periodic testing Periodic tests of emergency lighting luminaires must be performed according to EN50172 clause 7 2 3 and 7 2 4 Switch on in the emergency mode each month by simulation of a failure of the supply to the normal lighting for a period sufficient to ensure that each lamp is illuminated Twice per year each luminaire shall be...

Страница 8: ...8 11 ...

Страница 9: ...kovanou osobou LT Šiame šviestuve esantį šviesos šaltinį ir išorinis lankstus kabelis gali pakeisti tik jo gamintojas arba jo serviso atstovas arba atitinkamas kvalifikuotas asmuo LV Gaismas avotu ko satur šis gaismeklis un ārējais elastīgais kabelis var samainīt tikai ražotājs vai tā servisa pārstāvis vai līdzīgi kvalificēta persona EE Selles valgustis sisalduvat valgusallikat ja väline painduvat...

Страница 10: ...per assicurarela massima resistenzaper tutta la durata NL Om een veilig gebruikvan ditproductgedurende zijn helelevensduur te garanderen dienthetopslaan installeren gebruiken bedienenen onderhouden ervan exactte worden uitgevoerdin overeenstemmingmetde instructies in deze handleidingen ofanderedoor ons geleverde instructies Nietopvolgen van deze instructies maaktuwgarantieaansprakenongeldig Bouten...

Страница 11: ...отере прав на гарантию Болты для которых на чертеже указан крутящий момент необходимо затягивать калиброванным динамометрическим ключом Для обеспечения максимальной прочности изделия в течение всего срока службы болты завинченные в ходе предварительной сборки необходимо подтянуть до указанного момента SK Uskladnenie inštalácia používanie a údržba produktov je potrebné postupovať presne podľa pokyn...

Страница 12: ...s not form part of any quotation or contract is believed to be accurate and reliable and may be changed without notice No liability will be accepted by the publisher for any consequence of its use Publication thereof does not convey nor imply any license under patent or other industrial or intellectual property rights Signify Holding The Netherlands 2020 Signify Holding ...

Отзывы: