background image

EU Declaration of Conformity 

The Wolf LinkEx™ LED Temporary Luminaire (LX-400) meets all relevant provisions of the 

2014/34/EU Explosive Atmospheres (ATEX Equipment) Directive by virtue of the issued 

EU type examination certificate, demonstrating compliance with all relevant harmonised 

standards and essential health and safety requirements.

The Wolf LinkEx™ LED Temporary Luminaire is a leadlamp with a durable enclosure 

construction of polycarbonate with polyurethane protective rings. Models are available 

in a variety of input voltages. Approved as Group II, Category 2 equipment for use 

in zone 1 & 2 potentially explosive gases, vapours, mists and dusts where the T4 

temperature class/135ºC maximum surface temperature permits.  
Certification/Approval code:  

         II 2 GD 

Ex eb mb op is IIC T4 Gb (-20ºC 

 Ta 

 +55ºC) 

Ex tb op is IIIC T135ºC Db IP67*
EU Type examination certificate: 

SIRA12ATEX3177X

Notified body:  Baseefa  Ltd. Rockhead Business Park, 

Staden Lane, Buxton, SK17 9RZ, UK

Notified body number: 

1180

 

Harmonised standards applied: EN60079-0:2012 + A11:2013, EN60079-7:2015,  

EN60079-18:2015, EN60079-31:2014, EN60079-28:2015.
Ingress protection level 

IP67*

 to EN60529:1992

The Wolf LinkEx™ LED Temporary Luminaire is certified compliant with the  

2014/30/EU EMC Directive.

To the following harmonised standards BS EN 50015:2013, BS EN 61000-3-2: 2006 

+A2:2009, BS EN 61000-3-3: 2013 and BS EN 61547: 2009

Alex Jackson – Managing Director,

Wolf Safety Lamp Company Ltd.

IECEx Scheme Certification

Certificate number: 

IECEx SIR 12.0070X

Certification/Approval code:  

Ex eb mb op is IIC T4 Gb (-20ºC 

 Ta 

 +55ºC)

Ex tb op is IIIC T135ºC Db IP67*
Standards applied: IEC60079-0:2011, IEC60079-7:2015,

IEC60079-18:2014, IEC60079-31:2013, IEC60079-28:2015.
Ingress protection level 

IP67*

 to IEC60529:1992

*Some variants of plugs/sockets may reduce the IP (Ingress Protection) rating.

e.g. ATX and CEAG IP66, Stahl Sockets IP54 rated.

IMPORTANT: SPECIAL CONDITIONS OF USE (X)

1.

The user/installer shall ensure that, when the Luminaire is fitted with a previously 

certified plug that has associated special conditions for safe use, they shall take into 

account any restrictions or conditions for safe use that are applicable to these devices.

2.

Linkable luminaires fitted with Marechal sockets are certified for low impact risk 

use only, do not expose to shocks greater than 4 joules.

EQUIPMENT USE

1.

Read this document carefully before first use of the Wolf LinkEx™ LED Temporary 

Luminaire and retain for future reference.

2.

Check the rating label to ensure the Wolf LinkEx™ LED Temporary Luminaire 

is suitable for the supply provided, ambient temperature present and the 

environmental conditions.

3.

In areas where processes that induce circulating currents in the earth system are 

being undertaken, such as electric welding, it is the user’s responsibility to ensure 

there is no potential difference between the supply earth and the earth local to the 

luminaire. If a potential difference exists there is a risk of arcing should the luminaires

end cap fixings or metal gland come into contact with local metal work. In these 

situations, the luminaire should also be locally earth bonded with a flexible cable, 

no longer than 2 meters, with a conductor area of 6mm2 minimum. The luminaire 

must be de-energised during connection or disconnection of the local earth bond. 

An external Earth Bonding Stud is available in the spares list and can be retro 

fitted in place of one of the end cap retaining screws.

4.

Safe Operating Voltage Indicator (SOVI). The Wolf LinkEx™ LED Temporary Luminaire 

incorporates SOVI technology to highlight to the user if the product is operating 

outside of the certified maximum  and recommended minimum voltage range. 
The LX-400SH../T4/. 110/230 versions operating over 264V AC will pulse dim 

the light. The luminaire must not be used over this voltage.

When operating below 90V AC** the dimmed light will pulse brighten.

**The light output reduces incrementally as the supply voltage falls below 

100V AC. The luminaire will shut down if the supply voltage continues to fall.

The LX-400SL../T4/. 24/48 versions operating over 50V AC/DC will pulse dim 

the light. The luminaire must not be used over this voltage. When operating below 

18V AC/DC*** the dimmed light will pulse brighten.

***The light output reduces incrementally as the input voltage falls below 19V  

AC/DC. The luminaire will shut down if the supply voltage continues to fall.

If connecting a large number of luminaires check for SOVI indication on all the 

lamps in the string. Guidance on lamp connection and extensions can be found at 

www.wolf-safety.co.uk

5.

The Wolf LinkEx™ LED Temporary Luminaire enclosure is constructed from 

polycarbonate parts, check Ex area for potential contact to corrosive and/or 

aggressive substances.

6.

The Wolf LinkEx™ LED Temporary Luminaire is class 1 earthed electrical 

equipment, using 3 core cable. 

7.

Ex e terminal blocks must have all terminals fully tightened down even if a 

conductor is not fitted. On the six way terminal block, tighten screws to 0.6Nm, 

on the 4 way terminal block tighten to 1.8Nm.

8.

ATEX/IECEx certified cable glands must be used and be suitable for the type of 

cable used. 

9.

Ensure cable is rated for the ambient temperature the Wolf LinkEx™ LED Temporary

Luminaire will be used in, standard SY cable is not rated for use below -5ºC.

10.  Inspect cable for damage at regular intervals. 

11. Damaged equipment should be withdrawn and repaired as necessary before 

being put back in to service, in accordance with EN60079-17. 

12. Luminaires must not be opened in Hazardous Areas.

13. When the Wolf LinkEx™ LED Temporary Luminaire is used in temporary 

installations two mounting points must be used, see Wolf bracket fixing kits and 

associated accessories. 

14. The Wolf LinkEx™ LED Temporary Luminaire can be carried whilst energised/illuminated.

MAINTENANCE

1.

Isolate the Wolf LinkEx™ LED Temporary Luminaire from the power supply before 

carrying out any maintenance work.

2.

To replace LED strip, replace entire tray (see spares list).

3.

External plastic components have an anti static coating. Use only a dilute water/

detergent mix to clean.

4.

IMPORTANT. No modifications are permitted to the Wolf LinkEx™ LED Temporary 

Luminaire, all spare parts must be purchased from the manufacturer, unauthorized 

modifications or spare parts will invalidate certification. 

5.

Insulation testing must be carried out to IEC, EN standards to the correct rating 

i.e. 250V DC for 24/48V versions and 500V DC for 110/230VAC versions, Live 

and neutral cables must be shorted together and the voltage applied between 

earth and this connection.

ELECTRICAL DATA

CHANGING CABLE OR SOCKETS

See attached diagrams.
Remove the two securing screws from the cable entry end cap, remove end cap. 

Disconnect the input cable. To remove the enclosure tube, slide tube over the tray 

assembly. With the tube removed the blank cap (non linkable Luminaire) or socket  

and cap (linkable Luminaire) can be removed by removing the two internal screws; care 

must be taken to retain the sealing washers fitted to the screws and dome nuts.  

If required the socket cap can then be removed, if the socket is replaced ensure correct 

sealing washers are used. Re-assembly is the reverse procedure.  

Take care not to trap/crush wires, ensure all seals are present and in good condition.

FAULT FINDING

If a Wolf LinkEx™ LED Temporary Luminaire fails to function, check input cable 

continuity and terminations.  If satisfactory, test the output fuse to each LED strip. Only 

replace with Wolf encapsulated fuse of the correct rating. On 24/48V versions replace 

all fuses to LED strips if either has failed.

SPARE PARTS LIST

See attached diagram.

DISPOSAL OF WASTE MATERIAL

Disposal of packaging, LinkEx™ LED Temporary Luminaire products, old LED trays and 

electronics should be carried out in accordance with national regulations. (WEEE)
The Wolf Safety Lamp Co. Ltd has a policy of continuous product improvement.  

Changes in design details may be made without prior notice.
Prices and design are subject to alteration without notice. All products sold are subject 

to our conditions of sale. A copy of these instructions with any relevant revisions can be 

found at 

www.wolf-safety.co.uk

Wolf LinkEx

TM

 LED Temporary Luminaire 

Operation and Maintenance Instructions 

Please Retain – Read Before Use

Wolf LinkEx

TM

 LED Temporary Luminaire

Parts List 

WOLF SAFETY LAMP COMPANY

Saxon Road Works, Sheffield, S8 0YA, England

Tel: +44 114 255 1051    Fax: +44 114 255 7988

 

E-mail: [email protected]  Website: www.wolf-safety.co.uk

WOLF SAFETY LAMP COMPANY

Saxon Road Works, Sheffield, S8 0YA, England

Tel: +44 114 255 1051    Fax: +44 114 255 7988

 

E-mail: [email protected]  Website: www.wolf-safety.co.uk

LX-507 Issue 2

DF 330

Item No. 

Part No: 

Spare Part Description 

Quantity required per lamp 

180

o

 Models          360

o

 Models

 

LX-602

Bump Ring (pack of 2)  

1

LX-304

Tube Seal Ring (pair) 

1

LX-370

Tube 

1

LX-622

Cap Seal 5mm and Tube Seal 10mm 

(1 off of each for each end of the lamp) 

LX-306

Cable Entry End Cap 

1

LX-312

ATX Socket End Cap 

1

LX-314

Stahl Socket End Cap 

1

LX-310

CEAG Socket End Cap 

1

LX-316

Blank End Cap Non Link 

1

10 

LX-1044

CEAG Socket 110V 

1

11 

LX-1045

CEAG Socket 230V 

1

12 

LX-1043

CEAG Socket 24V 

1

13 

LX-1047

Stahl Socket 110V 

1

14 

LX-1050

ATX Socket 110V 

1

15 

LX-1051

ATX Socket 230V 

1

16 

LX-1049

ATX Socket 24V 

1

17 

LX-684

Ex e 6 Way Weidmuller Terminal Block and 

Screws M3x20, LED Output

18 

LX-624

24/48V LED Driver and Fittings 

1

19 

LX-640

110/230V LED Driver and Fittings 

1

20 

LX-618

180° LED Strip Assembly and Tray 

1

21 

LX-636

360° LED Top Tray Assembly 

1

22 

LX-637

360° LED Bottom Tray Assembly and Fittings 

1

23 

LL-311

Trumpet Gland 

1

24 

LX-408

Gland Nut 

1

25 

LX-658

Dowty Seals M6, M6x30 Screws, M5 Dome nuts, 

M5 Dowty Seals and M5x12 Cap Heads (2 of each) 

26 

LX-656

Weidmuller MK6 4 Way Terminal Block 

and Screws M3x22 and Backing Plate, Cable Input 

27 

LX-680

Magnet bracket Kit (pack of 2) 

1

28 

LX-1258

M6 External Earth Bonding Stud 

Items not shown on the exploded view diagram

LX-691

1 Amp LED Fuse (pack of 2) 

1

LX-654

Hanging / Shoulder Strap (pack of 2) 

1

LX-545/3

Protective Film (pack of 3) 

1

Link

Ex 

LED

MODEL

SOVI Range

Freq Hz

POWER WATT

VA

LX-400SL../T4/..24V

18-50VAC

50/60

27.1

41.2

18-50VDC

27.1

LX-400SL../T4/..48V

18-50VAC

50/60

26.9

51.2

18-50VDC

26.9

LX-400SH.. /T4/..110V

90-264VAC

50/60

30.5

31.2

LX-400SH.. /T4/..230V

90-264VAC

50/60

27.6

28.5

Отзывы: