You can read the error buffer in below ways:
• On screen via the SAM/CSM (if you have a picture).
Example:
–
ERROR: 000 000 000 000 000
: No errors detected
–
ERROR: 013 000 000 000 000
: Error code 13 is the last and only detected error
–
ERROR: 034 013 000 000 000
: Error code 13 was detected first and error code 34 is the last detected (newest) error
• Via the blinking LED procedure (when you have no picture).
5.2.3 Error codes overview
In this chassis only “layer 2” error codes are available and point to problems on the SSB. They are triggered by LED blinking
when CSM is activated. Only the following layer 2 errors are defined:
5.2.4 How to Clear the Error Buffer
The error code buffer is cleared in the following cases:
• By using the CLEAR command in the SAM menu
• By using the CLEAR command in the Factory mode:
• By using the following key sequence on the remote control transmitter: “
062599
” directly followed by the
OK
button.
• If the contents of the error buffer have not changed for 50 hours, the error buffer resets automatically.
Note:
If you exit SAM by disconnecting the mains from the television set, the error buffer is not reset.
Содержание 32PHT5102/56