Meridian 3
5. Color Temp confirmation
Connect the signal to the monitor, the monitor displays white-picture, use CA-210 to measure the Color Temp of the
screen center and select the OSD to make sure whether the Color Temps accord with the SPEC.
CIE
coordinates
11500K 9300K 8200K 7500K
6500K/sRGB
sRGB 5000K
x
0.270±0.02 0.283±0.02 0.291±0.02
0.298±0.02
0.313±0.02 0.313±0.02 0.345±0.02
y
0.281±0.02 0.297±0.02 0.306±0.02
0.314±0.02
0.329±0.02 0.329±0.02 0.357±0.02
6. How to enter into the factory mode:
1. Connect the video source and power off the monitor.
2. Press
and
buttons at the same time, power on the monitor, and then press the menu again; the
picture will appear on the top left corner.
3. Select the “Factory” and press the “MENU” button to enter the factory mode.