RoHS required
·
WEEE required.
·
Resin type/selection refer to Project Book Section 7.2 Plastic material.
5.8 If paint is used
·
RoHS required
·
WEEE require
·
If new painting type need to implement, refer to UN-D 1235.
5.9 Plastic mold tooling
·
Tooling to be designed to minimize cosmetic defects induced by molding process (sink, blush, weld
lines, gate marks, ejector marks, etc.). Refer to "TYV61-90007".
·
Painting to cover up cosmetic defects due to molding is strongly discouraged.
·
China RoHS mark requested.
All Plastics to be Flame Retardant UL 94-V0 or Better (if monitor weighs less than 18kg; UL94-V0 is
OK).
Base / Pedestal to be Flame Retardant UL 94-HB.
All major plastic parts (bezel, back cover, base) need to be molded from same resin.
ABS V0 is allowed to implement in China region for monitor body major plastic parts (bezel, back
cover, base).
Plastic resin type selection should be referred to "TY R83-2-9002-1".
5.11
The texture area and texture no should follow Philips make-up sheet.
The exterior surfaces shall have a uniform texture.
Philips must approve the mold texturing.
Detail document for texture refer to "UN-D249", "UN-D 600".
5.13
Must meet Kensington_slot.spec "TYE-M0004".
MMD request metal plate in Kinsington hole.
Regulatory label / Carton label should follow Philips requirement.
Detail document refer to Philips Engineering Reference Book.
5.15
Product dimension / Weight (Refer to SHT 191 )
Unit dimension : 483mm (W) * 402mm(H) * 215mm(D)
Packed unit dimension: 579mm(W) * 513mm(H) * 267 mm(D) for WW
: 579mm(W) * 513mm(H) * 267 mm(D) for China
: 8.6Kg (Including I/F cable 240 g)
:
5.16
Transportation standards refer to TYE-M0002.
Packaging and wrapping shall be sufficient to protect the product against damage or loss
during shipment from the supplier to the destination specified in the purchase order. All
packaging materials are subject to test and evaluation per TYE-M0002. The cushion material
shall be constructed using EPS material.
5.16.2
Transportation Test
The overall test refer to TYE-M0002.
Vibration, drop test should be performed at ambient temperature(20° C to 23
o
C) and relative humidity
(40% to 65% ).
BRAND : PHILIPS
20 inch LCD Monitor
TYPE
:200PW8
2007-11-23
590
2007-11-23
GENERAL PRODUCT SPECIFICATION(Continued)
Содержание 200PW8ES/00
Страница 31: ...31 HUDSON 8 Wiring Diagram h t t p w w w w j e l n e t ...
Страница 32: ...32 HUDSON 8 Block Diagram h t t p w w w w j e l n e t ...
Страница 40: ...Scaler Board Layout 1 top left 40 HUDSON 8 h t t p w w w w j e l n e t ...
Страница 41: ...41 HUDSON 8 Scaler Board Layout 1 top right h t t p w w w w j e l n e t ...
Страница 42: ...Scaler Board Layout 1 bottom left 42 HUDSON 8 h t t p w w w w j e l n e t ...
Страница 43: ...43 HUDSON 8 Scaler Board Layout 1 bottom right h t t p w w w w j e l n e t ...
Страница 44: ...44 HUDSON 8 Scaler Board Layout 2 h t t p w w w w j e l n e t ...
Страница 52: ...52 HUDSON 8 Key Board Layout h t t p w w w w j e l n e t ...
Страница 82: ...82 HUDSON 8 Different Parts List This chapter will be updated h t t p w w w w j e l n e t ...
Страница 83: ...83 HUDSON 8 Revision List Manual 3122 785 17640 First release ALL chapters h t t p w w w w j e l n e t ...