17S1AB
LCD
85
Safety Test Requirements
All units that are returned for service or repair must
pass the original manufactures safety tests. Safety
testing requires both Hipot and Ground Continuity
testing.
HI-POT TEST INSTRUCTION
1.Application requirements
1.1 All mains operated products must pass the Hi-Pot
test as described in this instruction.
1.2 This test must be performed again after the
covers have been refitted following the repair ,
inspection or modification of the product.
2. Test method
2.1 Connecting conditions
2.1.1 The test specified must be applied between the
parallel blade plug of the main scord and all
accessible metal parts of the product.
2.1.2 Before carrying out the test, reliable conductive
connections must be ensured and thereafter be
maintained throughout the test period.
2.1.3 The mains switch(es) must be in the "ON"
position.
2.2 Test Requirements
All products should be HiPot and Ground Continuity
tested as follows:
Condition
Hi-Pot Test for
products where
the mains input
is 220V AC
Hi-Pot Test for
products where
the mains input
is 110V AC
Ground
Continuity
Test
requirement
Test
voltage
2820VDC
(2000VAC)
1700VDC
(1200VAC)
Test current:
25A, AC
Test time: 3
seconds
Resistance
required:
<=0.09+Rohm,
R is the
resistance of
the mains
cord.
91 220CW9
LCD
Test time 3 seconds
1 seconds
Trip
current
(Tester)
Set at 100uA for
Max limit;
Set at 0.1uA for
Min limit.
5mA
Ramp
time
(Tester)
Set at 2 seconds
ġ
2.2.1 The minimum test duration for Quality Control
Inspector must be 1 minute.
2.2.2 The test voltage must be maintained within the
specified v 5%.
2.2.3 There must be no breakdown during the test.
2.2.4 The grounding blade or pin of mains plug must
be conducted with accessible metal parts.
3. Equipments and Connection
3.1. Equipments
For example :
- Zentech 9032 PROGRAMMABLE AUT O SAFETY
TESTER
3.2. Connection
* Turn on the power switch of monitor before Hipot
and Ground Continuity testing.
4. Recording
Hipot and Ground Continuity testing records have to
be kept for a period of 10 years.
Содержание 17S1AB
Страница 19: ...17S1AB LCD 19 Service tool Hardware PCM code 12NC 5E L8215 001 996510019769 ...
Страница 20: ...20 17S1AB LCD Service tool Software FW writing tool Easy Writer V4 1 DDC writing tool Q EDID V16 ...
Страница 31: ...17S1AB LCD 31 Firmware Upgrade for CPU Step 4 Press Auto to update F W Step 5 Update OK ...
Страница 34: ...34 17S1AB LCD ORFN LDJUDP ...
Страница 40: ...6FDODU LDJUDP 40 17S1AB LCD ...
Страница 41: ...6FDODU LDJUDP 41 17S1AB LCD ...
Страница 45: ...Power Diagram C B A 45 17S1AB LCD ...
Страница 47: ...17S1AB LCD 47 RQWURO LDJUDP ...
Страница 49: ...LED Diagram C B A 49 17S1AB LCD ...
Страница 52: ...ġ ġ 52 17S1AB LCD ġ PHILIPS LOGO displayed while power on WEEE REQUIREMENT RoHS REQUIREMENT TCO 03 REQUIREMENT ...
Страница 77: ...17S1AB LCD 77 SORGHG 9LHZ 2 15 1 8 13 7 11 14 6 12 5 16 17 4 3 9 10 ...