17” CDT Color Monitor 107E7
23
x-ray protection
The x-ray ptotection(pin22) input XRAY provides a voltage detector with a precise voltage input for X-ray
protection .If the input voltage at XRAY exceeds the upper threshold for 150us to 300us,the system is forced to
shut down by switching off vertical-and B-drive signals. There are two different ways to handle the system in case
of XRAY occurrence:
1. If the x-ray latch enable bit UCXRAY[2] was set to “0” during startup the system will shut down without any
interference of the uC.The deflection controller is set to ldle mode. Restart of the system only possible due to
seitching power off/power on.
2. If register bit UCXRAY[2] was set to “1”,micro controller interaction is allowed .If the micro controller doesn’t
interrupt the system, the system will shut down to ldle mode. For any interaction of the micro controller the XRAY
occurrence has to be acknowledged by the micro controller by clearing the bit SY-STATUS[2].The micro controller
take over the control of the handling via software. The actual x-ray pin status can be read through bit SY-
STATUS[1].
Quartz Oscillator(pin45,pin46)
The quartz oscillator circuit is available on pins XTAL1(input) and XTAL2(output) and works together with an
external 48MHz 3
rd
overtone quartz.As a result the quartz oscillator is always running on 48MHz.Other quartz
crystal frequencies than 48 MHz cannot be used.External capacitors on XTAL1 and XTAL2 are not allowed.
B+ Control Function Block
The B+control block of the SAA4849P has the same behaviour as the TDA4856 with adapted threshol voltages.
The circuit allows the user to choose the trigger edge of the HDRV signal and the polarity of the output stage via
I
2
C-Bus.
The B+ control function block of the SAA4849P consists of an Operational Transconductance Amplifier(OTA), a
voltage comparator, a flip-flop and a discharge circuit. This configuration allows easy application for different B+
control concepts.
HPLL
The horizontal part contains a PLL,which works over the full frequency range from 25kHz to 140 kHz. This range
can be reduced by a ower and an upper frequency limit(Write Once Registers HPMAX and HPMIN).Via I
2
C bus the
number of 48MHz clock cycles is sent through the register. The slewing speed during mode change is also
programmable in a write once register (HSLEW)
After the clocks for the HPLL are switched on, the HPLL starts with a fixed freerunning frequency of 60 kHz. The
H-drive pulses are not active and the start up procedure is inhibited. The default setting of register bit HCONTROL [0]
will cause the HPLL to slew ,not switch. to the freerunning frequency defined in the I
2
C register HPFREE( the default
value is also 60 kHz).Independent on H-syncs which are possibly present. the HPLL will slew to that freerunning
frequency. To achieve an always defined starting point for the startup procedure, this procedure cannot be interrupted.
Содержание 107E7
Страница 12: ...17 CDT Color Monitor 107E7 12 ...
Страница 20: ...17 CDT Color Monitor 107E7 20 Fig 5 Fig 6 Step 4 Enter go into the next screen as shown Fig 7 Fig 7 ...
Страница 21: ...17 CDT Color Monitor 107E7 21 Step 5 Enter into Fig 8 Fig 8 Step 6 Enter into Fig 9 Fig 9 ...
Страница 35: ...17 CDT Color Monitor 107E7 35 8 Mechanical of cabinet front dis assembly ...
Страница 54: ...17 CDT Color Monitor 107E7 54 13 PCB Layout 13 1 Main PCB layout ...
Страница 55: ...17 CDT Color Monitor 107E7 55 13 2 CRPC Board layout ...