2.6.1 Features
•
AC line voltage range -
90Vac ~ 264Vac.
•
AC line frequency range -
50/60 Hz
±
3 Hz.
•
Input voltage transient -
300Vac for 10 seconds (China), 280Vac for 10 seconds (RoW).
•
Inrush current -
< 50 A at 240Vac cold start.
•
Earth leakage current -
< 1.0mA at 240Vac.
•
Power factor correction -
According to EN61000-3-2
2.6.2 Power Consumption
It is equipped with two-stage power saving management. A delay of 5 seconds before entering the power saving
state is required to avoid misunderstanding of display resolution and timing mode changes.
•
Power on -
< 75w. (Test requirements refer to EN61000-3-2)
•
Active off -
< 2w at 120Vac / 240Vac.
•
Switch off -
< 2w at 120Vac / 240Vac.
2.6.3 Power saving conditions
The monitor enters DPM off mode when no H&V sync or one of H-sync / V-sync input is absent. No message
appears before entering DPM mode.
2.6.4 Power recovery from power saving
Both H-sync and V-sync are detected.
Timing 10.
Resolution 1280
x
960
Pixel clock
108.000 MHz
H. Frequency
60.000 kHz
H. Total
16.667 us
H. Active display
11.852 us
H. Back porch
2.889 us
H. Sync. Width
1.037 us
V. Frequency
60.000 Hz
V. Total display
16.667 ms
V. Active display
16.000 ms
V. Back porch
0.600 ms
V. Sync. Width
0.050 ms
H/V sync
polarity
+ / +
Содержание 107E7
Страница 12: ...17 CDT Color Monitor 107E7 12 ...
Страница 20: ...17 CDT Color Monitor 107E7 20 Fig 5 Fig 6 Step 4 Enter go into the next screen as shown Fig 7 Fig 7 ...
Страница 21: ...17 CDT Color Monitor 107E7 21 Step 5 Enter into Fig 8 Fig 8 Step 6 Enter into Fig 9 Fig 9 ...
Страница 35: ...17 CDT Color Monitor 107E7 35 8 Mechanical of cabinet front dis assembly ...
Страница 54: ...17 CDT Color Monitor 107E7 54 13 PCB Layout 13 1 Main PCB layout ...
Страница 55: ...17 CDT Color Monitor 107E7 55 13 2 CRPC Board layout ...