![Philips Saeco Exprelia Series Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/philips-saeco/exprelia-series/exprelia-series_service-manual_1550645028.webp)
EXPRELIA 04 OPERATING LOGIC
Saeco International Group
Rev. 00 / June 2010
Page / 11
“Empty drip tray” - message
Function:
The residual water level is monitored using a capacitive
sensor. The sensor is located approximately halfway up the
upper edge of the drip tray. To ensure the best possible
use of the drip tray capacity, the sensor is located near to
a dam. Therefore, the drip tray
fi
lls up to the upper edge
of the dam and over
fl
ows inside, triggering the sensor and
thus the “Empty drip tray” message.
Drip tray
Switching
Switching
level sensor
level sensor
Total
Total
capacity
capacity
Sensor
4.12. Water level detection (drip tray)
4.11. Water level detection (water tank)
“Water low” message (water reserve)
Function:
The water level is monitored by a capacitative sensor, located one
third of the way up the water tank wall.
If the electronics assembly detects, by means of the sensor,
that the amount of water in the tank has dropped below the
above mentioned level, a water reserve remains available for the
dispensing process underway (this will cover 200 turbine pulses).
The product dispensing process will then come to an end.
If a dispensing cycle ends after the sensor has been triggered (in
the reserve) then the display “Water low” continues to be displayed
during the following dispensing cycle.
200 puls.
Sensor
Water tank
10
Содержание Exprelia Series
Страница 3: ...Saeco International Group Rev 00 June 2010 EXPRELIA CHAPTER 1 INTRODUCTION...
Страница 8: ...Saeco International Group Rev 00 June 2010 EXPRELIA CHAPTER 2 TECHNICAL SPECIFICATIONS...
Страница 12: ...Saeco International Group Rev 00 June 2010 EXPRELIA CHAPTER 3 CHAPTER 3 USER INSTRUCTIONS USER INSTRUCTIONS...
Страница 18: ...Saeco International Group Rev 00 June 2010 EXPRELIA CHAPTER 4 OPERATING LOGIC...
Страница 30: ...Saeco International Group Rev 00 June 2010 EXPRELIA CHAPTER 5 TROUBLESHOOTING...
Страница 38: ...Saeco International Group Rev 00 June 2010 EXPRELIA CHAPTER 6 CHAPTER 6 STANDARD CHECKS STANDARD CHECKS...
Страница 41: ...Saeco International Group Rev 00 June 2010 EXPRELIA CHAPTER 7 DISASSEMBLY...
Страница 51: ...Saeco International Group Rev 00 June 2010 EXPRELIA CHAPTER 8 CHAPTER 8 NOTES NOTES...
Страница 52: ...EXPRELIA 08 NOTES Saeco International Group Rev 00 June 2010 Page 01 01...
Страница 54: ...EXPRELIA 09 WATER CIRCUIT DIAGRAM Saeco International Group Rev 00 June 2010 Page 01 01...
Страница 55: ...Saeco International Group Rev 00 June 2010 EXPRELIA CHAPTER 10 CHAPTER 10 ELECTRICAL DIAGRAM ELECTRICAL DIAGRAM...
Страница 56: ...EXPRELIA 10 WIRING DIAGRAM Saeco International Group Rev 00 June 2010 Page 01 01...