5. INSTALLATION
The isolating transformers are designed for installation on a wall or the floor. It will be fixed by four
fastening screws. Please install the isolation transformer in a well ventilated area..
For installation a space in a locker or engine room of a diesel engine would suit. The isolating trans-
former has not to be installed in an engine room of a petrol engine, a battery locker and not in the
neighbourhood of petrol tanks ( danger of explosion).
For installation firstly the top cover must be removed. The cover is fixed by four M4 - crosshead-screws
on the top of the device. There are four holes at the bottom of the device for the mounting. The four
transportation locking screws have to be removed. After that the transformer can be screwed through
these holes to the wall or floor. There are also four higher-laying screws - they are for fixation of the
transformer to the housing - please don`t remove them.
The compression couplings have to be fixed on the front side and the input and output wires have to
be passed through.
Demounting the four transportation locking screws:
compression -
couplings
The isolating transformer will be fixed through this four holes on the bottom of the device.
Please pay attention, that the transformer has to be mounted electrically isolated
in case of metal hulls ! (f.e. on a wooden plate)
The fixing screws must be isolated from the hull too!
Page 8