background image

Slim Multi-Sensor PSM01                            

The   slim   multi-sensor   PSM01  has   door/window,   temperature   and

illumination, 3 sensors function in one, based on Z-Wave

TM

 technology.

Z-Wave

TM

  is   a   wireless   communication   protocol   designed   for   home

automation, specifically to remotely control applications in residential

and light commercial environments. The technology uses a low-power

RF radio embedded or retrofitted into home electronics devices and

systems, such as lighting, home access control, entertainment systems

and household appliances.

This device is one component of the Z-Wave

TM

  sensor system and is

designed to work with all other Z-Wave

TM

  enabled devices in a home

control network. The device adopt the Z-Wave

TM

 400 series chip, when

your   Z-Wave

TM

  network   system   is   all   made   by   Z-Wave

TM

  400   series

devices. The network system will have the advantages as below.

Concurrent multi-channel support reduces external interference.

Better RF range, improve about 10 meters in indoor.

Support 100 Kbps transmit speed, speed up communication.

Adding to Z-Wave

TM

 Network

There are two  tamper  keys  in  the device, one  is in the back  side,

another is in the front side. They have the same function. Both of them

can inclusion, exclusion, reset or association from Z-Wave

TM

 network.

In the first time, add the device into the Z-Wave

TM

 network.  First, make

sure the primary controller is in the inclusion mode. And then power on

the device, just take out the insulation Mylar in the back side of the 

device. The device will auto start the NWI (Network Wide Inclusion) 

mode. And it should be included in 5 seconds. You will see the LED 

light ON one second.

Function

Description

Inclusion

1. Have Z-Wave

TM

 Controller entered inclusion mode.

2. Pressing tamper key three times within 1.5 seconds

will enter inclusion mode.

3. After inclusion successful, the device will wake to 

receive the setting command from Z-Wave

TM

 

Controller about 20 seconds.

Exclusion

1. Have Z-Wave

TM

 Controller entered exclusion mode.

2. Pressing tamper key three times within 1.5 seconds

will enter exclusion mode.

Node ID has been excluded.

Reset

1. Pressing tamper key four times within 1.5 seconds 

and do not release the tamper key in the 4

th

 

pressed, and the LED will turn ON.

2. After 3 seconds the LED will turn OFF, after that 

within 2 seconds, release the tamper key. If 

successful, the LED will light ON one second. 

Otherwise, the LED will flash once.

3. IDs are excluded and all settings will reset to 

factory default.

1

Содержание PSM01

Страница 1: ...in the front side They have the same function Both of them can inclusion exclusion reset or association from Z WaveTM network In the first time add the device into the Z WaveTM network First make sure the primary controller is in the inclusion mode And then power on the device just take out the insulation Mylar in the back side of the device The device will auto start the NWI Network Wide Inclusio...

Страница 2: ...p the device immediately please remove the front cover and press the tamper key once The device will wake up 10 seconds Z WaveTM Message Report Door Window Report When the Door Window state changed the device will unsolicited to send the Sensor Binary Report to the nodes in the group 1 Sensor Type Door Window 0x0A Sensor Value 0x00 is closed 0xFF is opened Tamper Report When the 2 tamper keys in t...

Страница 3: ...on the device will check is it already adding to the network If doesn t it will auto start the NWI mode The LED will flash in every second and continue 30 seconds Until timeout or the device successful to inclusion by controller Wake When the power on the device will wake about 20 seconds In this duration the controller can communicate with the device Normally the device is always sleeping to save...

Страница 4: ...low steps 1 Using a tool like 1 to press 1 1 till hear a click sound 2 Hold the front cover and pull back 3 Hold the front cover and pull up Replace the new battery and install the cover back 1 Put the front cover bottom to 1 1 and press down 2 Push the front cover top to 2 1 Choosing a Suitable Location 1 Don t let the device facing the window or the sunlight 4 ...

Страница 5: ... tape one is thicker hereinafter referred to as A tape and another is thinner hereinafter referred to as B tape you can use A tape for the test at the beginning The right way for A tape installation is stick it to the position below tamper key The thicker tape won t let the tamper key close so the sensor will enter the test mode You may test if installed position is good or not by this way After f...

Страница 6: ...t3 Reserved Bit4 Disable delay 5 seconds to turn off the light when door window closed Bit5 Disable auto turn off the light after door window opened to turn on the light Bit6 Enable temperature monitoring When this bit enable the temperature changed 3 degree Fahrenheit it will report And also the temperature over 140 degree Fahrenheit it will report every 64 seconds 9 Turn Off Light Time 4 4 127 A...

Страница 7: ...tructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient ...

Страница 8: ...ng the collection systems available If electrical appliances are disposed of in landfills or dumps hazardous substances can leak into the groundwater and get into the food chain damaging your health and well being When replacing old appliances with new once the retailer is legally obligated to take back your old appliance for disposal at least for free of charge 8 ...

Отзывы: