background image

* Illumination Report:

When the door/window state changed, the device will unsolicited to

send the “Sensor Multilevel Report” to the nodes in the group 1.

Sensor Type: Luminance (0x03)

Note: To disable this functionality by setting the configuration setting

N0.5, the bit4 of the value to 1.

* Timing Report:

Beside   the   event   triggered  could  report  message,   the   device   also

support the timing unsolicited report of the status.

Battery level report: Every 6 hours report once in default.

It could be changed by configuration setting NO. 10.

Low battery report: When the battery level is too low, every 30

minutes will report once.

Door/window state report: Every 6 hours report once in default.

It could be changed by configuration setting NO. 11.

Illumination level report: Every 6 hours report once in default.

It could be changed by configuration setting NO. 12.

Temperature report: Every 6 hours report once in default.

It could be changed by configuration setting NO. 13.

Power Up Procedure

* Battery Power Check

When   the   power   up,   the   device   will   detect   the   power   level   of   the

battery immediately. If the power level is too low, the LED will continue

flash about 5 seconds. Please change another new battery.

* NWI

When the power on, the device will check is it already adding to the

network? If doesn't, it will auto start the NWI mode. The LED will flash

in every second and continue 30 seconds. Until timeout or the device

successful to inclusion by controller.

* Wake

When the power on, the device will wake about 20 seconds. In this

duration, the controller can communicate with the device. Normally the

device is always sleeping to save the battery energy.

Operation Mode

There are two operation mode, “Test Mode” and “Normal Mode”, the

“Test Mode” is for the user test the sensor function when installation.

When the event triggered, normally the LED won't indicated, unless the

battery is in the low level, the LED will flash once. And in the “Test

Mode” the LED also will light ON one second.

When the event triggered, the device will report the messages to the

nodes in the group 1. The messages also include the temperature and

the illumination level. The user can switch the report by configuration

setting NO. 5. When the event triggered, if the environment luminance

is less than the setting of the configuration  setting  NO. 4, the device

will emit the signal to turn ON the lighting equipment, those nodes in

the group 2.  If the event is door/window close, it will delay about 5

seconds and emit the signal to turn OFF the lighting equipment.

Notice: 

When the tamper key of the back side is in the released state,

the device always in the “Test Mode”.

3

Содержание PSM01

Страница 1: ...in the front side They have the same function Both of them can inclusion exclusion reset or association from Z WaveTM network In the first time add the device into the Z WaveTM network First make sure the primary controller is in the inclusion mode And then power on the device just take out the insulation Mylar in the back side of the device The device will auto start the NWI Network Wide Inclusio...

Страница 2: ...p the device immediately please remove the front cover and press the tamper key once The device will wake up 10 seconds Z WaveTM Message Report Door Window Report When the Door Window state changed the device will unsolicited to send the Sensor Binary Report to the nodes in the group 1 Sensor Type Door Window 0x0A Sensor Value 0x00 is closed 0xFF is opened Tamper Report When the 2 tamper keys in t...

Страница 3: ...on the device will check is it already adding to the network If doesn t it will auto start the NWI mode The LED will flash in every second and continue 30 seconds Until timeout or the device successful to inclusion by controller Wake When the power on the device will wake about 20 seconds In this duration the controller can communicate with the device Normally the device is always sleeping to save...

Страница 4: ...low steps 1 Using a tool like 1 to press 1 1 till hear a click sound 2 Hold the front cover and pull back 3 Hold the front cover and pull up Replace the new battery and install the cover back 1 Put the front cover bottom to 1 1 and press down 2 Push the front cover top to 2 1 Choosing a Suitable Location 1 Don t let the device facing the window or the sunlight 4 ...

Страница 5: ... tape one is thicker hereinafter referred to as A tape and another is thinner hereinafter referred to as B tape you can use A tape for the test at the beginning The right way for A tape installation is stick it to the position below tamper key The thicker tape won t let the tamper key close so the sensor will enter the test mode You may test if installed position is good or not by this way After f...

Страница 6: ...t3 Reserved Bit4 Disable delay 5 seconds to turn off the light when door window closed Bit5 Disable auto turn off the light after door window opened to turn on the light Bit6 Enable temperature monitoring When this bit enable the temperature changed 3 degree Fahrenheit it will report And also the temperature over 140 degree Fahrenheit it will report every 64 seconds 9 Turn Off Light Time 4 4 127 A...

Страница 7: ...tructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient ...

Страница 8: ...ng the collection systems available If electrical appliances are disposed of in landfills or dumps hazardous substances can leak into the groundwater and get into the food chain damaging your health and well being When replacing old appliances with new once the retailer is legally obligated to take back your old appliance for disposal at least for free of charge 8 ...

Отзывы: