turn on the light. For dimmer equipment 
1 to 100 means the light strength.

4 Light 

Threshold

99

0~100

Setting the illumination threshold to turn 
on the light. When the event triggered 
and the environment illumination lower 
then the threshold, the device will turn 
on the light.
0 means turn off illumination detected 
function. And never turn on the light.
1 means darkest.
99 means brightest.
100 means turn off illumination detected
function. And always turn on the light.

Notice:

 In none test mode, only the 

value in 1 to 99 will enable the 
illumination detected function and 
update the illumination value.

5 Operation 

Mode

0

0~127

Bit0: Reversed. 
Bit1: Reversed. 
Bit2: Disable the door/window function.
Bit3: Setting the temperature scale.
  0: 

Fahrenheit

, 1:

Celsius

Bit4: Disable illumination report after 
event triggered.
Bit5: Disable temperature report after 
event triggered.

6 Multi-Sensor 

Function 

Switch

4

0~127 Multi-Sensor function switch. Using bit to

control.
Bit0: Disable magnetic integrate 
illumination.
Bit1: Reserved, always 1.
Bit2: Reserved, always 1.
Bit3: Reserved.
Bit4: Disable delay 5 seconds to turn off 

the light, when door/window closed.
Bit5: Disable auto turn off the light, after
door/window opened to turn on the 
light. 
Bit6:Enable temperature monitoring.
When this bit enable, the temperature 
changed 3 degree Fahrenheit, it will 
report.
And also the temperature over 140 
degree Fahrenheit, it will report every 64
seconds.

9 Turn Off Light 

Time

4

4~127

After turn on the light, setting the delay 
time to turn off the light. 8 seconds per 
tick, and minimum time is 32 seconds, 
default tick is 4 (32 seconds).

10 Auto Report 

Battery Time

12

1~127

The interval time for auto report the 
battery level. 30 minutes per tick and 
minimum time is 30 minutes, default tick
is 12 (6 hours).

11

Auto Report 

Door/Window 

State Time

12

1~127

The interval time for auto report the 
door/window state. 30 minutes per tick 
and minimum time is 30 minutes, default
tick is 12 (6 hours).

12

Auto Report 

Illumination 

Time

12

1~127

The interval time for auto report the 
illumination. 30 minutes per tick and 
minimum time is 30 minutes, default tick
is 12 (6 hours).

13

Auto Report 

Temperature 

Time

12

1~127

The interval time for auto report the 
temperature. 30 minutes per tick and 
minimum time is 30 minutes, default tick
is 12 (6 hours).

6

Содержание PSM01

Страница 1: ...in the front side They have the same function Both of them can inclusion exclusion reset or association from Z WaveTM network In the first time add the device into the Z WaveTM network First make sure the primary controller is in the inclusion mode And then power on the device just take out the insulation Mylar in the back side of the device The device will auto start the NWI Network Wide Inclusio...

Страница 2: ...p the device immediately please remove the front cover and press the tamper key once The device will wake up 10 seconds Z WaveTM Message Report Door Window Report When the Door Window state changed the device will unsolicited to send the Sensor Binary Report to the nodes in the group 1 Sensor Type Door Window 0x0A Sensor Value 0x00 is closed 0xFF is opened Tamper Report When the 2 tamper keys in t...

Страница 3: ...on the device will check is it already adding to the network If doesn t it will auto start the NWI mode The LED will flash in every second and continue 30 seconds Until timeout or the device successful to inclusion by controller Wake When the power on the device will wake about 20 seconds In this duration the controller can communicate with the device Normally the device is always sleeping to save...

Страница 4: ...low steps 1 Using a tool like 1 to press 1 1 till hear a click sound 2 Hold the front cover and pull back 3 Hold the front cover and pull up Replace the new battery and install the cover back 1 Put the front cover bottom to 1 1 and press down 2 Push the front cover top to 2 1 Choosing a Suitable Location 1 Don t let the device facing the window or the sunlight 4 ...

Страница 5: ... tape one is thicker hereinafter referred to as A tape and another is thinner hereinafter referred to as B tape you can use A tape for the test at the beginning The right way for A tape installation is stick it to the position below tamper key The thicker tape won t let the tamper key close so the sensor will enter the test mode You may test if installed position is good or not by this way After f...

Страница 6: ...t3 Reserved Bit4 Disable delay 5 seconds to turn off the light when door window closed Bit5 Disable auto turn off the light after door window opened to turn on the light Bit6 Enable temperature monitoring When this bit enable the temperature changed 3 degree Fahrenheit it will report And also the temperature over 140 degree Fahrenheit it will report every 64 seconds 9 Turn Off Light Time 4 4 127 A...

Страница 7: ...tructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient ...

Страница 8: ...ng the collection systems available If electrical appliances are disposed of in landfills or dumps hazardous substances can leak into the groundwater and get into the food chain damaging your health and well being When replacing old appliances with new once the retailer is legally obligated to take back your old appliance for disposal at least for free of charge 8 ...

Отзывы: