Operation mode. Using bit to control.
Size: 1 Byte, Default Value: 0
Setting
Description
1
Reserve.
2
1 means test mode, 0 means normal mode. Notice: This bit only effect by the DIP Switch setting to “cust
mode”, otherwise it decides by DIP Switch setting to Test or Normal Mode
4
Disable the door/window function. (1:Disable, 0:Enable)
8
Setting the temperature scale. 0: Fahrenheit, 1:Celsius
16
Disable the illumination report after event triggered. (1:Disable, 0:Enable)
32
Disable the temperature report after event triggered. (1:Disable, 0:Enable)
64
Reserve.
128
Disable the back key release into test mode. (1:Disable, 0:Enable)
Parameter 6: Mult-Sensor Function Switch
Multisensor function switch. Using bit to control.
Size: 1 Byte, Default Value: 4
Setting
Description
1
Disable magnetic integrate illumination to turn ON the lighting nodes in the association group 2. (1:Disab
0:Enable)
2
Reserve.
4
Reserve.
8
Reserve.
16
Disable delay 5 seconds to turn off the light, when door/window closed. (1:Disable, 0:Enable)
32
Disable auto turn off the light, after door/window opened to turn on the light. (1:Disable, 0:Enable)
64
Reserve.
128
Reserve.
Parameter 7: Customer Function
Customer function switch, using bit control.
Size: 1 Byte, Default Value: 4
Setting
Description
1
Reserve.
2
Reserve.
4
Reserve.
8
Disable send out BASIC OFF after door closed. (1:Disable, 0:Enable)
16
Notification Type, 0: Using Notification Report. 1: Using Sensor Binary Report.
32
Disable Multi CC in auto report. (1:Disable, 0:Enable)
64
Disable to report battery state when the device triggered. (1:Disable, 0:Enable)
128
Reserve.
Parameter 8: PIR Re-Detect Interval Time
In the normal mode, after the PIR motion detected, setting the re-detect time. 8 seconds per tick, default tick is 3 (24 seconds).Setting the suitable value to
received the trigger signal too frequently. Also can save the battery energy.Notice: If this value bigger than the configuration setting NO. 9. There is a period
light turned off and the PIR not start detecting.
Size: 1 Byte, Default Value: 3
Setting
Description
1 - 127
PIR Re-Detect Interval Time