Philio PHI PST02-1C Скачать руководство пользователя страница 5

06-10-2020 15

:

11

Pagina 5 van 9

http://manual.zwave.eu/backend/make.php?lang=en&sku=PHI_PST02-1C

controller will usually perform all necessary configurations. The wakeup interval is a tradeoff between maximal battery life time and the desired responses o
device. To wakeup the device please perform the following action: 

Press any key once, the device will awake 10 seconds.

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

1.  Make sure a device is in factory reset state before including. In doubt exclude before include.
2.  If inclusion still fails, check if both devices use the same frequency.
3.  Remove all dead devices from associations. Otherwise you will see severe delays.
4.  Never use sleeping battery devices without a central controller.
5.  Dont poll FLIRS devices.
6.  Make sure to have enough mains powered device to benefit from the meshing

Firmware-Update over the Air

This device is capable of receiving a new firmware 'over the air'. The update function needs to be supported by the central controller. Once the controller sta
update process, perform the following action to confirm the firmware update: The device support the Z-Wave firmware update via OTA. Before starting the p
please remove the front cover of the device. Otherwise the hardware check will be failed. Let the controller into the firmware update mode, and then press t
tamper key once to start the update.  After finish the firmware download, the LED will start flash in every 0.5 second. At that time, please don"t remove the b
otherwise it will cause the firmware broken, and the device will no function. After the LED stop flash, it is recommended that the user power up the device. C
After remove the battery, please wait about 30

seconds, and then re-install the battery.

Association - one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a dif
device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they a
related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will rece
same wireless command wireless command, typically a 'Basic Set' Command.

Association Groups:

Group Number

Maximum Nodes

Description

1

8

Receiving the report message, like triggered event, temperature, illumination etc.

2

8

Light control, the device will send the “Basic Set” command

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock fu
enhanced features.

IMPORTANT:

 Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be t

value minus 256. For example: To set a parameter to 200

it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same

applies: Values greater than 32768 may needed to be given as negative values too.

Parameter 2: Basic Set Level

Setting the BASIC command value to turn on the light 

Size: 1 Byte, Default Value: 255

Setting

Description

0

turn off the light

1 - 100

the light strength.

254

turn on the light.

Parameter 4: Light Threshold

Setting the illumination threshold to turn on the light. When the event triggered and the environment illumination lower then the threshold, the device will turn
light. 0 means turn off illumination detected function. And never turn on the light.
Notice: In none test mode, only the value in 1 to 99 will enable the illumination detected function and update the illumination value. 

Size: 1 Byte, Default Value: 99

Setting

Description

0

turn off illumination detected function.

1 - 100

1 means darkest. 99 means brightest. 100 means turn off illumination detected function. And always turn
light.

Parameter 5: Operation Mode

Содержание PHI PST02-1C

Страница 1: ...ing every message two way communication and every mains powered node can act as a repeater for other nodes meshed network in case the receiver is not in direct wireless range of the transmitter This device and every other certified Z Wave device can be used together with any other certified Z Wave device regardless of brand and origin as long as both are suited for the same frequency range If a devi...

Страница 2: ... to make sure the very device is excluded properly from this network Reset to factory default This device also allows to be reset without any involvement of a Z Wave controller This procedure should only be used when the primary controller is inope 1 Pressing tamper key four times within 1 5 seconds and do not release the tamper key in the 4th pressed and the LED will light ON 2 After 3 seconds th...

Страница 3: ...ntroller is in the inclusion mode And then power on the devi take out the insulation Mylar in the back side of the device The device will auto start the NWI Network Wide Inclusion mode And it should be included seconds You will see the LED light ON one second Let the controller associate with the device into the first group any light switch that intend to be turned on when the device trig please as...

Страница 4: ...r entered exclusion mode 2 Pressing tamper key three times within 1 5 seconds to enter the exclusion mode 3 Node ID has been excluded Node Information Frame The Node Information Frame NIF is the business card of a Z Wave device It contains information about the device type and the technical capabilities The and exclusion of the device is confirmed by sending out a Node Information Frame Beside this...

Страница 5: ...n one device controlling another device is called association In order to control a dif device the controlling device needs to maintain a list of devices that will receive controlling commands These lists are called association groups and they a related to certain events e g button pressed sensor triggers In case the event happens all devices stored in the respective association group will rece sa...

Страница 6: ...erve 4 Reserve 8 Reserve 16 Disable delay 5 seconds to turn off the light when door window closed 1 Disable 0 Enable 32 Disable auto turn off the light after door window opened to turn on the light 1 Disable 0 Enable 64 Reserve 128 Reserve Parameter 7 Customer Function Customer function switch using bit control Size 1 Byte Default Value 4 Setting Description 1 Reserve 2 Reserve 4 Reserve 8 Disable...

Страница 7: ...etting Description 0 127 Auto Report Illumination Time Parameter 13 Auto Report Temperature Time The interval time for auto report the temperature 0 means turn off auto report temperature The default value is 12 The tick time can setting by the configura Size 1 Byte Default Value 12 Setting Description 0 127 Auto Report Temperature Time Parameter 20 Auto Report Tick Interval The interval time for a...

Страница 8: ... ZC10 14080018 Z Wave Product Id 0x013C 0x0002 0x000E Frequency Europe 868 4 Mhz Maximum transmission power 5 mW Supported Command Classes Association Association Group Information Battery Sensor Binary Configuration Device Reset Locally Firmware Update Md Manufacturer Specific Multi Command Sensor Multilevel Notification Powerlevel Security Version Wake Up Zwaveplus Info Controlled Command Classes B...

Страница 9: ... removing Z Wave devices from the network Association is a control relationship between a controlling device and a controlled device Wakeup Notification is a special wireless message issued by a Z Wave device to announces that is able to communicate Node Information Frame is a special wireless message issued by a Z Wave device to announce its capabilities and functions c 2020 Z Wave Europe GmbH Ant...

Отзывы: