background image

The table below provides an operation summary of basic Z-Wave™

functions.   To   add/remove/associate   PAT14,   please   refer   to   the
instruction of certified Z-Wave™ Primary Controller.

Function

Description

Without

Node ID

New PAT14 does not have Node ID until it is included
by a Z-Wave™ Controller.

Add

(Classic

Inclusion)

1.

Set Z-Wave™  Controller to inclusion mode by fol-
lowing   the   instructions   provided   by   the   controller
manufacturer.

2.

Press the button on PAT14 three times within 3 sec-
onds to enter inclusion mode.

SmartStart

1. To initiate the SmartSart process, please type in the

first five digits of DSK string or scan the QR code.
The  QR   Code   can   be   found   on   PAD15  or   in   the
box.
Ex:   DSK:

 18112-24021-58001-62259-57092-

27453-08187-47408

2. PAT14  is   supported   with   SmartStart,   it   can   be

added   to   Z-Wave™   network   by   scanning   the   Z-
Wave™ QR code on the product.

3. Without further actions, PAT14 will be automatically

included   in   a   certified   Z-Wave™   Controller   with
SmartStart   inclusion   ability   in   10   minutes   after   it
turned on.

Remove

(Exclusion)

1.

Set your Z-Wave™ controller to exclusion mode by
following the instructions provided by the controller
manufacturer.

2. Press the button on PAT14 three times within 3 sec-

onds to enter exclusion mode.

3. Node ID will be excluded.

Reset

1. Press the button of PAT14 four times within 3 sec-

onds   and   hold   the   last   press   until   the   LED   light
turns off.

Adding a node ID allocated by Z-Wave™ Controller means 
inclusion. Removing a node ID allocated by Z-Wave™ 
Controller means exclusion.

The situation of including/excluding of the node ID can be 
checked from the Z-Wave™ Controller.

Function Reset: The Reset procedure can only be used 
when PAD15 cannot be recognized by the Z-Wave™ 
Primary Controller.

Notice 1:

 Always RESET a Z-Wave

TM

 device before trying to add it to a 

Z-Wave

TM

 network 

LED Light Indication

The LED light indicates the different modes of the PAD15

State Type

LED Indication

Without

Node ID

Under   normal   operation,   when   the   PAD15   has
not been allocated a node ID, the LED light will
flash on and off alternately at 1-second intervals.
By pressing the On/Off button, LED light will stop
flashing temporarily.

Learning

Flashes when learning is successful

Z-Wave

TM

  Multi Channel  Association

PAT14   just   be   set   to   send   reports   to   multi   channel   associated   Z-

Wave™   devices.   It   supports   five   association   groups   with   five   nodes
support for group 1 ~ group 5. 

Group 1, the will report

3

Содержание PAT14

Страница 1: ...work act as repeaters to increase the stability and reliability of the Z Wave network The product is supported with Over the Air OTA feature for firmware upgrade Specification Rated DC5 24V 6mA RF distance Min 40M indoor 100M outdoor line of sight RF Frequency 868 40 MHz 869 85 MHz EU 908 40 MHz 916 00 MHz US 920 9MHz 921 7MHz 923 1MHz TW SG Thai KR RF Maximum Power 10dBm Peak 10dBm Average Dimens...

Страница 2: ...For Instruction to http www philio tech com Add to Remove from Z WaveTM Network There is a button with LED indicator in front of PAT14 It is used to dim on off the light and carry out the inclusion exclusion reset or association of PAT14 from Z wave controller When the fist power one the LED indicator flashes once per second for 30 seconds With the SmartStart function PAT14 will be automatically i...

Страница 3: ...tions provided by the controller manufacturer 2 Press the button on PAT14 three times within 3 sec onds to enter exclusion mode 3 Node ID will be excluded Reset 1 Press the button of PAT14 four times within 3 sec onds and hold the last press until the LED light turns off Adding a node ID allocated by Z Wave Controller means inclusion Removing a node ID allocated by Z Wave Controller means exclusio...

Страница 4: ... status Temperature report Every 1 hours report once in default It could be changed by setting the configuration NO 5 Notice The configuration NO 5 could be setting to zero to disable the auto report And the configuration NO 6 could change the tick interval the default value is 12 if setting to 1 that means the minimum auto report interval will be one minute And please notice if setting this value...

Страница 5: ...uto Report Temperat ure Time 5 0 127 Temperaturn auto report time 0 disable Default is 5 Tick Interval can setting by configuration No 4 4 Auto Report Tick Interval 12 0 0xFF The interval time for auto report each tick Setting this configuration will effect configuration No 3 Units of one minute Caution1 Setting to 0 means turn off all auto report function Caution2 The value is unsigned byte the r...

Страница 6: ...y Class CAUTION Risk of explosion if battery is replaced by an incorrect type Dispose of used battery according to the instructions Choosing a Suitable Location 1 The suitable ambient temperature for the module device is 10 C 40 C 2 Do NOT place the module device direct under sunlight in a humid place or in any location where they may contact moisture dirt dust 3 Do NOT place the module device whe...

Страница 7: ... to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation FCC Caution Any changes or modi...

Отзывы: