DEVICE_RESET_LOCALLY_NOTIFICATION.
Group 2, End Point 1 will report ( channel 1)
SENSOR_MULTILEVEL_REPORT_TEMPERATURE
Group 3, End Point 2 will report ( channel 2)
SENSOR_MULTILEVEL_REPORT_TEMPERATURE
Group 4, End Point 1 will report (channel 1)
NOTIFICATION_REPORT_HEAT_V4
Group 5, End Point 2 will report (channel 2)
NOTIFICATION_REPORT_HEAT_V4
Z-Wave
TM
Notification
This function default is disable, to enable this function by setting the
configuration NO.3 bit4~7.And set threshold by setting the
configuration NO.11 ~ 14.
Z-Wave
TM
Message Report
* Temperature differential report:
This function default is enabled, to disable this function by setting the
configuration NO.7 to 0.
In the default, when the temperature is changed to plus or minus 0.5
degree Celsius, the device will report temperature information to the
nodes in the lifeline group.
The device will measure the temperature in every 1 seconds. And if the
temperature is over 140 degree Fahrenheit (60 degree Celsius), the
device will always report in each measurement.
* Timing Report:
The device support the timing unsolicited report of the status.
•
Temperature report: Every 1 hours report once in default.
It could be changed by setting the configuration NO. 5.
Notice
: The configuration NO. 5 could be setting to zero to disable the
auto report. And the configuration NO. 6 could change the tick interval,
the default value is 12, if setting to 1, that means the minimum auto
report interval will be one minute. And please notice if setting this value
to zero, that means disable all of the timing report except the low
battery detection.
Over The Air (OTA) Firmware Update
The device support the Z-Wave firmware update via OTA.
Let the controller into the firmware update mode, and then press the
tamper key once to start the update.
At that time,
please don't remove the battery
, otherwise it will cause
the firmware broken, and the device will no function.
After the LED stop flash, it is recommended that the user power up the
device.
Caution
: After remove the battery, please wait about 30
seconds, and then re-install the battery.
Z-Wave Configuration Settings
Notice:
* All of the configuration, the data size is 1.
* The configuration mark with star(*), means after the remove the
setting still keep, don't reset to factory default. Unless the user execute
the “RESET” procedure.
* The reserve bit or not supported bit is allowed any value, but no effect.
4