background image

Meter

5

Highest granted Security Class

Multi Channel Association

3

Highest granted Security Class

Notification

8

Highest granted Security Class

Powerlevel

1

Highest granted Security Class

Version

3

Highest granted Security Class

Note

: Please make sure that the intensity of the plug of the electrical device must

be 16A and have same head as the enclosed plug before inserting to the socket.

Disposal 

This marking indicates that this product should not be disposed
with other household wastes throughout the EU. To prevent possi-
ble harm to the environment or human health from uncontrolled
waste disposal, recycle it responsibly to promote the sustainable
reuse of material resources. To return your used device, please use
the return and collection systems or contact the retailer where the
product was purchased. They can take this product for environ-
mental safe recycling.

Company of License Holder

Philio Technology Corporation

Address of License Holder

8F., No.653-2, Zhongzheng Rd., Xinzhuang Dist.,

New Taipei City 24257, Taiwan(R.O.C)

www.philio-tech.com

Содержание PAN45

Страница 1: ...er unplug and reconnect the switch will re set its overload condition to normal status Specification Operating Voltage 100V 240V 50Hz 60Hz Maximum Load Ampere 13A Resistive load Range Minimum 40 m in door 100m outdoor line of sight Operating Temperature 0 C 40 C 85 RH max Location In door use Frequency Range Z Wave 868 40MHz 869 85MHz EU Zigbee 2405 2480MHz RF Maximum Power 10dBm Peak 10dBm Averag...

Страница 2: ...oosing a Suitable Location 1 Do not locate the Module facing direct sunlight humid or dusty place 2 The suitable ambient temperature for the Module is 0 C 40 C 3 Do not locate the Module where exists combustible substances or any source of heat e g fires radiators boiler etc 4 After putting it into use the body of Module will become a little bit hot of which phenomenon is normal Product overview W...

Страница 3: ...seconds will enter inclusion mode Smart start 1 To initiate the SmartSart pro cess please type in the first five digits of DSK string or scan the QR code The QR Code can be found on PAN45 or in the box Ex DSK 18112 24021 58001 62259 57092 27453 08187 47408 2 PAN45 is supported with Smart Start it can be added to Z Wave network by scanning the Z Wave QR code on the product 3 Without further actions...

Страница 4: ...r into ex clusion mode by following the in structions provided by the controller manufacturer 2 Pressing On Off button five times within 3 seconds will enter exclusion mode 3 Node ID has been excluded LED flashes 0 1s every 3s last for three minutes Reset 1 Pressing On Off button six times within 3 seconds and hold at least 5s at the sixth time to reset device Use this procedure only in the event ...

Страница 5: ...witch on the load to the ON position 4 To manually turn ON the Switch press and release the On Off button The LED will turn ON and the load plugged into the Switch will also turn ON 5 To manually turn OFF the Switch simply press and release the On Off but ton The LED will turn OFF and the load plugged into the Switch will also turn OFF Programming 1 Basic Command Class Binary Switch Command Class ...

Страница 6: ...over 5 it will send Meter report to the nodes of Grouping 1 Meter Report Command Command Class Meter Meter Report Rate Type 0x01 Meter Type 0x01 Precision 1 Scale 0x02 Size 4 Meter Value W 2 1 3 Overload alarm report When PAN45 detects the current is more than 14 5A it will send Alarm Report to Group 1 node The content of Alarm Report Alarm report command Command_Class_Alarm Alarm_Report Alarm Typ...

Страница 7: ...he node Meter Get Command Command Class Meter Meter Get Scale 0x04 V Meter Report Command Command Class Meter Meter Report Rate Type 0x01 Meter Type 0x01 Precision 1 Scale 0x04 Size 2 Meter Value V Example Scale 0x04 V Precision 1 Size 2 2 Bytes of V Meter Value 1 0x09 V Meter Value 2 0x01 V AC load Voltage Meter Value 1 256 Meter Value 2 230 5 V 2 2 5 AC load current I When receiving Meter Get Co...

Страница 8: ... mode 1 0 1 1 0 Disable 1 5 2 10 3 15 4 10 9 Switch status report mode 1 0 1 1 0 Disable 1 Enable 3 1 Watt Meter Report Period If the setting is configured for 1hour set value 720 PAN45 will report its instant power consumption to Group1 node every 1 hour The maximum inter val to report its instant power consumption is 45 hours 5s 32767 3600 45hr When the setting is 0 PAN45 will disable Watt auto ...

Страница 9: ...ill be on only one second then LED keeps off 3 8 Watt differential mode The default setting is 1 5 Whenever Watt value of PAN45 changes over 5 of last reading value it will send Meter report to the group 1 nodes However if Watt differential mode as 0 the unsolicited report will be disabled 3 9 Switch status report mode The default setting is 1 Enable Whenever PAN45 manually switch on or off it wil...

Страница 10: ...hat this product should not be disposed with other household wastes throughout the EU To prevent possi ble harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device please use the return and collection systems or contact the retailer where the product was purchased They can take ...

Отзывы: