background image

[Command Class Multilevel Switch, Multilevel Switch Report, 

Value = 0x63 (TOP)]

2-3 MULTILEVEL SWITCH START LEVEL CHANGE:

This is the command which user can move the shutter up to the top or down to

the bottom.

[Command Class Multilevel Switch, Multilevel Switch Start Level Change, 

Up/Down Value]

2-3.1 Up/Down Bit:

If Up/Down Bit=0x00 Shutter move up

If Up/Down Bit=0x01 Shutter move down

If Up/Down Bit=0x03 no move

[Command Class Multilevel Switch, Multilevel Switch Start Level Change, 

Up/Down=0x00] control the shutter to the top (0x63)

[Command Class Multilevel Switch, Multilevel Switch Start Level Change, 

Up/Down=0x01] control the shutter to the bottom (0x00)

[Command Class Multilevel Switch, Multilevel Switch Start Level Change, 

Up/Down=0x03] Don't move the shutter or stop the moving shutter

 ATT.  1. Ignore Start Level

Start Level

Dimming Duration

Inc/Dec

Step size can 

not be used.

      2

PAN34 can not control the speed of motor.

3. It may have some distance error caused by motor start up time.

4. If user found the error become significant, you may using S1 or S2 move 

shutter to the end or remote move shutter to 0% and 100%, and that will 

automatically calibrate this error.

2-3.4 

MULTILEVEL SWITCH STOP LEVEL CHANGE:

When receive Multilevel Switch Stop Level change Command PAN34 will stop the 

motor.

Z-Wave’s Groups introduction (

Maximum 5 nodes

)

There is only one group called Lifeline

there is only 5 nodes for Group1 which sup-

port MULTILEVEL_SWITCH_REPORT

METER_REPORT_COMMAND_V3

 NOTI-

FICATION_REPORT and DEVICE_RESET_LOCALLY_NOTIFICATION. 

3-1

 Device reset locally notification :

When PAN34 is reset manually, it will send a DEVICE_RESET_LOCALLY_

NOTIFICATION to the nodes of group 1.

3-2 Report the shutter position 

Every time when user press S1 or S2 and let shutter to move, PAN34 will report the 

position status to controller, and at the moving process when change over 10%  

PAN34 will send Multilevel Switch Report to Group 1 as well.

Multilevel Switch Report

Ex. Report position at 30% 

[Command Class Multilevel Switch

 Multilevel Switch Report

Value = 30(%)]

3-3 Meter Command Class

7

Содержание PAN34

Страница 1: ...This device must be used in conjunction with a Security Enabled Z Wave Controller in order to fully utilize all functions Its functionality and supported command classes is identical when included as a secure and non secure device The new smart relay calibration technology can reduce the inrush current caused by the load and let the module work perfectly with many kind of Roller Shutter This in wa...

Страница 2: ...0 MHz 923 10 MHz Taiwan RF Maximum Power 10dBm Peak 10dBm Average Communication Protocol Z Wave OTA Yes FCC ID RHHPAN34 Dimensions 47 5 x 39 x16 mm Wire 0 75mm 18AWG Specifications are subject to change and improvement without notice Troubleshooting Symptom Cause of Failure Recommendation The PAN34 not working and LED off 1 The PAN34 is not connect to the Main power 2 The PAN34 break down 1 Check ...

Страница 3: ...ducing changes into the configuration must be always performed with disconnected voltage Choosing a Suitable Location 1 Do not locate the Module facing direct sunlight humid or dusty place 2 The suitable ambient temperature for the Module is 0 C 40 C 3 Do not locate the Module where exists combustible substances or any source of heat e g fires radiators boiler etc 4 After putting it into use the b...

Страница 4: ...n mode by following the instructions provided by the controller manufacturer 2 Pressing Include button three times within 2 seconds will enter exclusion mode Node ID has been excluded LED 0 5s On 0 5s Off En ter auto inclusion Reset 1 Pressing Include button three times within 2 seconds will enter inclusion mode Use this procedure only in the event that the primary controller is lost or otherwise ...

Страница 5: ... of three continue stages The shutter move to the TOP in first stage and move to the BOTTOM in second stage and move to the TOP again in third stage Then PAN34 will know the total range from the BOTTOM to the TOP 2 During the shutter calibration process any emergencies happen you can press and release the include button to stop the process 3 If user found the direction is reverse this may cause by...

Страница 6: ...evel Switch Set Value 0x63 control the shutter to the top 0x63 Command Class Multilevel Switch Multilevel Switch Set Value 0x00 0 control the shutter to the bottom 0x00 Command Class Multilevel Switch Multilevel Switch Set Value 0xFF 255 control the shutter to the the most recent non zero level Command Class Multilevel Switch Multilevel Switch Set Value 0x01 0x62 control the shutter to the positio...

Страница 7: ...ome distance error caused by motor start up time 4 If user found the error become significant you may using S1 or S2 move shutter to the end or remote move shutter to 0 and 100 and that will automatically calibrate this error 2 3 4 MULTILEVEL SWITCH STOP LEVEL CHANGE When receive Multilevel Switch Stop Level change Command PAN34 will stop the motor Z Wave s Groups introduction Maximum 5 nodes Ther...

Страница 8: ...xample Meter Value 1 0x00 W Meter Value 2 0x00 W Meter Value 3 0x03 W Meter Value 4 0xEA W Meter W Meter Value 3 256 Meter Value 4 100 2W 3 3 2 Accumulated Power Consumption KW h When receiving Meter Get Command it will report Meter Report Command to the node asked Meter Get Command Command Class Meter Meter Get Scale 0x00 KW h Meter Report Command Command Class Meter Meter Report Rate Type 0x01 M...

Страница 9: ... Scale 0x05 I Precision 2 Size 2 2 Bytes of I Meter Value 1 0x01 I Meter Value 2 0x21 I AC load current Meter Value 1 256 Meter Value 2 2 89 A 3 3 5 load power factor PF When receiving Meter Get Command it will report Meter Report Command to the node asked Meter Get Command Command Class Meter Meter Get Scale 0x06 PF Meter Report Command Command Class Meter Meter Report Rate Type 0x01 Meter Type 0...

Страница 10: ...e Push button 2 Two Push button 3 Total 2 0 6000 0 1 Second 0 0 The time depends on Moving Range Calibration moving time of curtain 1 6000 0 1s 600s 4 Watt threshold 1 1 5 Watt 1 The threshold is a judgment for motor running or not 5 Watt differential 1 0 1 1 0 It will not report Watt when change over 5 1 It will report watt value when the differential is over 5 6 Timer offset for motor start runn...

Страница 11: ...this moving short pressed S2 again the shutter just keeps moving down toward BOTTOM 0x00 The easy way to stop this moving is short pressing S1 When in Two Push Button switch mode S1 or S2 are pressed and not released and PAN34 receive any control moving command from Z Wave RF Ex BASIC_SET BINARY_SWITCH_SET MULTILEVEL_SWITCH_SET MULTILE VEL_SWITCH_START_LEVEL_CHANGE or MULTILEVEL_SWITCH_STOP_LEVEL_...

Страница 12: ...urces To return your used device please use the return and collection systems or contact the retailer where the product was purchased They can take this product for environmental safe recycling Philio Technology Corporation 8F No 653 2 Zhongzheng Rd Xinzhuang Dist New Taipei City 24257 Taiwan R O C www philio tech com FCC Interference Statement This equipment has been tested and found to comply wi...

Страница 13: ...erence that may cause undesired operation FCC Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment This transmitter must not be co located or operating in conjunction with any other antenna or transmitter 警語 取得審驗證明之低功率射頻器材 非經核准 公司 商號或使用者均不得擅自變更頻 率 加大功率或變更原設計之特性及功能 低功率射頻器材之使用不得影響飛航安全及干擾合法通信 經發現有...

Отзывы: