![Philio Technology Corporation PSP06 Скачать руководство пользователя страница 8](http://html.mh-extra.com/html/philio-technology-corporation/psp06/psp06_manual_1537993008.webp)
NO.
Name
Def.
Vali
d
Description
0
Bit3
: Reserve.
0
Bit4
: Reserve.
0
Bit5
: Reserve.
0
Bit6
: Reserve.
0
Bit7
: Reserve.
4
Basic ON
Level
0xFF
All
Setting the BASIC command value.
When the PIR trigger, send the
BASIC CC to the group 2.
5
Delay Send
Basic Off
Timer
1
All
How many timer delay to send basic
off after PIR trigger. Unit : 10
second.
6
PIR Re-trigger
time
10
All
After the PIR motion detected,
setting the re-detect time. 1 seconds
per tick, default tick is 10 (Unit : 1
seconds).
Setting the suitable value to prevent
received the trigger signal too
frequently. Also can save the battery
energy.
7
PIR Sensitivity
1
1 ~ 2
PIR sensitivity settings.
1 means the hight sensitivity
2 means the lowest sensitivity
Z-Wave Supported Command Class
Command Class
Version
Required Security Class
Z-Wave Plus™ Info
2
None
Security
1
None
Security 2
1
None
Supervision
1
None
Transport Service
2
None
Association
2
Highest granted Security Class
Association Group
Information
3
Highest granted Security Class
Device Reset Locally
1
Highest granted Security Class
Firmware Update Meta
Data
5
Highest granted Security Class
Indicator
3
Highest granted Security Class
Manufacturer Specific
2
Highest granted Security Class
Multi-Channel Association
3
Highest granted Security Class
Powerlevel
1
Highest granted Security Class
Version
3
Highest granted Security Class
Configuration
4
Highest granted Security Class
Notification
8
Highest granted Security Class
Battery
1
Highest granted Security Class
8