Philio Technology Corporation PSP06 Скачать руководство пользователя страница 6

Installation

1.  In the first time, add the device into the Z-Wave

TM

  network.   First,

make sure the primary controller is in the inclusion mode. And then
power on the device, just take out the insulation Mylar in the back side
of the device. The device will auto start the SmartStart Include mode.
You will see the LED light ON one second. (refer to fig. 1)

2. Let the controller associate with the device into the first group, any
light switch that intend to be turned on when the device trig please
associate with the device into the second group.

3. In the accessory pack, There is double-coated tape.  you can use a
double-coated  type   for  the   test  at   the   beginning.  The   right  way   for
double coated type installation is to stick it to the position of the back.
the   sensor   will   enter   the   test   mode,   You   may   test   if   the   installed
position is good or not by this way (refer to fig. 2 and fig. 3)

          

   fig 1                                      fig 2

 
            

fig 3

6

Содержание PSP06

Страница 1: ...veTM 700 series chip when your Z WaveTM network system is all made by Z WaveTM 700 series devices The network system will have the advantages as below Concurrent multi channel support reduces external interference Better RF range improve about 10 meters in indoor Support 100 Kbps transmit speed speed up communication Specification Power 3VDC CR123A lithium battery Battery life 10 years RF distance...

Страница 2: ...or mechanically crushing or cutting of a battery that can result in an explosion leaving a battery in an extremely high temperature surrounding environment that can result in an explosion or the leakage of flammable liquid or gas a battery subjected to extremely low air pressure that may result in an explosion or the leakage of flammable liquid or gas The marking information is located at the bott...

Страница 3: ...operable 1 Pressing tamper key four times within 1 5 seconds and do not release the tamper key in the 4th pressed and the LED will light ON 2 After 3 seconds the LED will turn OFF after that within 2 seconds release the tamper key If successful the LED will light ON one second Otherwise the LED will flash once 3 IDs are excluded and all settings will reset to factory default SmartStart 1 Product h...

Страница 4: ...Report Both the 2 tamper keys are pressed over 5 seconds The device will into the alarm state In that state if any one of the tamper keys be released the device will unsolicited to send the report to the nodes in the group 1 Notification Report V8 Notification Type Home Security 0x07 Event Tampering Product covering removed 0x03 Timing Report Beside the event triggered could report message the dev...

Страница 5: ...the firmware download please don t remove the battery otherwise it will cause the firmware broken and the device will no function After the LED stop flash it is recommended that the user power up the device Caution After remove the battery please wait about 30 seconds and then re install the battery Battery Installation User need change the battery while the device is showing battery low message P...

Страница 6: ... 2 Let the controller associate with the device into the first group any light switch that intend to be turned on when the device trig please associate with the device into the second group 3 In the accessory pack There is double coated tape you can use a double coated type for the test at the beginning The right way for double coated type installation is to stick it to the position of the back th...

Страница 7: ...hat the logical path of an intruder would cut across the fan pattern rather than directly towards the detector Z Wave Configuration Settings Notice All of the configuration the data size is 1 All of the configuration after the remove the setting still keep don t reset to factory default Unless the user execute the RESET procedure The reserve bit or not supported bit is allowed any value but no eff...

Страница 8: ...ns the hight sensitivity 2 means the lowest sensitivity Z Wave Supported Command Class Command Class Version Required Security Class Z Wave Plus Info 2 None Security 1 None Security 2 1 None Supervision 1 None Transport Service 2 None Association 2 Highest granted Security Class Association Group Information 3 Highest granted Security Class Device Reset Locally 1 Highest granted Security Class Fir...

Страница 9: ...uarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or televi sion reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and r...

Отзывы: